Eaton / Cutler-HammerGHB3090S1
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | GHB |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Frame Type | GHB |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Pow-R-Line Panelboards, Series C Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | GHB |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Frame Type | GHB |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Pow-R-Line Panelboards, Series C Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed |
Eaton / Cutler-HammerGHB3090S1
Eaton / Cutler-HammerGHB3100S1
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Series | GHB |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 14kA @ 480Y/277VAC, 14kA @ 125/250VDC |
| Frame Type | GHB |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Pow-R-Line Panelboards, Series C Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 10-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 10 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, Federal Specification W-C-375B, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed |
This G-frame breaker is designed to mount into Eaton Pow-R-Line panelboards (including PRL1a, PRL2a, and PRL3a assemblies). It is also compatible with Series C enclosures, switchboards, and motor control centers designed for bolt-on branch breakers.
Yes. Eaton acquired the Westinghouse electrical distribution division and Cutler-Hammer. The Eaton GHB3090 is manufactured to the same specifications and serves as a direct drop-in replacement for legacy Westinghouse GHB3090 and Cutler-Hammer GHB3090 catalog numbers.
No. While it provides a 14 kAIC interrupting rating at 480Y/277 VAC for solidly grounded wye systems, Type GHB breakers are not suitable for use on 3-phase, 3-wire 480V ungrounded Delta systems.
Yes, this Series C circuit breaker is HACR rated, meaning it is certified for use in providing branch circuit protection for heating, air conditioning, and refrigeration equipment.
Yes, this thermal-magnetic breaker supports reverse feeding. This allows electricians flexibility when configuring line and load conductor connections within the enclosure.
No. The breaker is equipped with a non-interchangeable, fixed thermal and fixed magnetic trip unit. Neither the continuous overload rating nor the instantaneous short-circuit pickup can be modified.
The standard pressure terminals on the GHB3090 are rated for both copper and aluminum (Cu/Al) conductors, accepting wire sizes ranging from 10 AWG up to 1/0 AWG.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.