Eaton / Cutler-HammerQBGFEP2040
Quantity
New
Quantity
Eaton / Cutler-HammerQBGFEP2040
Eaton / Cutler-HammerQBGFEP2030
Eaton / Cutler-HammerQBGFEP2025
Eaton / Cutler-HammerQBGFEP2020
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | QBGFEP2050 |
| Series | QBGFEP |
| Amperage | 50A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | BAB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Eaton Pow-R-Line Panelboards |
| Wire Gauge | 8-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Special Classification | GFEP |
|---|---|
| Available Options | Auxiliary Switch, Bell Alarm |
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, UL 1053, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Common Trip |
This bolt-on breaker is designed for Eaton Pow-R-Line commercial panelboards. It specifically fits panels configured for BAB or QB-frame branch breakers, such as the Pow-R-Line 1a and 1X series.
It features a 30mA ground fault trip sensitivity. This classifies it as Ground Fault Equipment Protection (GFEP), which prevents damage to machinery and circuits, rather than 5mA personnel protection (GFCI).
No. Because it has a 30mA trip threshold, it is strictly rated for equipment protection (such as for heat trace cables or heavy machinery). For personnel protection in wet locations, a 5mA Class A GFCI breaker is required.
The breaker is equipped with a pigtail neutral wire. This coiled wire must be routed and connected securely to the panel neutral bar to enable proper ground fault sensing and ensure the breaker operates correctly.
Yes. Eaton acquired both Cutler-Hammer and Westinghouse. This breaker is the exact, interchangeable replacement for legacy Cutler-Hammer and Westinghouse breakers bearing the QBGFEP2050 catalog number.
The LIG designation means the breaker incorporates Long-Time (thermal overload), Instantaneous (magnetic short-circuit), and Ground-Fault trip functions to provide comprehensive circuit and equipment protection.
Instead of snapping onto the bus, this breaker features bolt-on brackets that must be mechanically fastened directly to the panelboard bus with screws. This provides a high-reliability connection common in commercial and industrial distribution panels.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.