| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | EGE3045FFG |
| Series | EGE |
| Amperage | 45A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600Y/347VAC, 125/250VDC |
| Phase | 3 |
| AIC Rating | 35kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600Y/347VAC, 10kA @ 125/250VDC |
| Frame Type | EG |
|---|---|
| Terminal Type | Lugs |
| For Use With | Eaton Pow-R-Line 1a Panelboards, Eaton Pow-R-Line 2a Panelboards, Series G Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-1/0 AWG |
| Max Wire | 1/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Handle Mechanism, Motor Operator |
|---|---|
| Accessories | Line and Load Terminals |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, IEC, KEMA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Current Limiting, Reverse Feed, High-Speed Blow-Open Action |
This EG-frame breaker is compatible with Eaton Pow-R-Line 1a and Pow-R-Line 2a panelboards. It can also be installed in Series G enclosures, motor control centers, and switchboards.
Yes, the breaker comes standard with line and load lugs. These terminals accept wire gauges ranging from 14 AWG to 1/0 AWG.
The "FFG" suffix indicates the breaker is equipped with a fixed thermal and fixed magnetic trip unit, and that standard line and load lugs are included from the factory.
Yes, in addition to its AC ratings, this thermal-magnetic breaker is rated for DC systems with an interrupting capacity of 10kA at 125/250VDC.
No, this breaker features a fixed thermal and fixed magnetic trip unit. The long-time and instantaneous trip functions are factory-set and cannot be adjusted in the field.
Equipped with a thermal-magnetic trip unit, this breaker provides standard LI protection. This includes long-time protection against overloads and instantaneous protection against short circuits.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.