| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-C32/3-NA |
| Series | FAZ |
| Amperage | 32A |
| Poles | 3 |
| Mounting Style | DIN Rail |
| Voltage | 240VAC, 480Y/277VAC, 96VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC, 10kA @ 480Y/277VAC, 10kA @ 96VDC |
| Frame Type | FAZ |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | DIN Rail Systems, Industrial Control Panels |
| Wire Gauge | 18-6 AWG (1 wire), 18-10 AWG (2 wires) |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | C |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Alarm Switch, Padlock Attachment, Busbar System |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | ABS, CE, CSA, cULus, DNV, IEC, Lloyd's, UL, VDE |
| Temp Rating | -25C to 75C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Trip-Free Mechanism, Visual Trip Indicator, RoHS Compliant |
The C-curve characteristic means the magnetic trip point is set between 5 and 10 times the rated current. This makes it ideal for applications with medium inrush currents, such as small transformers, lighting, and control circuits, preventing nuisance tripping during startup.
Yes, it is a UL 489 listed miniature circuit breaker. This certification allows it to be used as a primary branch circuit overcurrent protective device, unlike UL 1077 devices which are only rated for supplementary protection.
It is designed to snap directly onto a standard 35mm DIN rail, allowing for quick installation and replacement inside industrial control panels and machinery enclosures.
Yes, it features a current-limiting design that interrupts fault currents within one half cycle. This rapid response reduces the peak let-through energy, providing superior protection for sensitive downstream electrical components.
Yes, it is dual-rated for AC and DC applications. It can safely interrupt up to 10kA at 96VDC, allowing it to protect DC power supplies and industrial automation equipment.
The box lug terminals accommodate 18 to 6 AWG when using a single conductor. If you are landing two wires in the same terminal, the capacity is limited to 18 to 10 AWG.
Yes, it utilizes a trip-free design. This safety feature ensures the breaker will still trip during an overcurrent or short circuit event even if the operating handle is physically held in the ON position.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.