Eaton / Cutler-Hammer PDG23G0125TFFL Molded Case Circuit Breaker

  • 125A
  • 3 Pole
  • Panel Mount
Eaton / Cutler-Hammer PDG23G0125TFFL
Molded Case Circuit Breaker
Brand Eaton / Cutler-Hammer
SKU PDG23G0125TFFL
Select Item Condition
Earn 1190 SuperPoints
  • 125A
  • 3 Pole
  • Panel Mount

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Eaton / Cutler-Hammer PDG23G0125TFFL - 125A 3 Pole Molded Case Circuit Breaker

Eaton / Cutler-Hammer PDG23G0125TFFL - 125A 3 Pole Molded Case Circuit Breaker

New

$1,190.46 In Stock

Quantity

Similar Items

Description

Delivering 35kAIC of interrupting capacity at 480VAC, the PDG23G0125TFFL is a globally rated Frame 2 molded case circuit breaker. It provides 125A of reliable power distribution with fixed thermal and magnetic trip settings for LI defense. This panel-mount MCCB is engineered for Eaton Power Defense enclosures. It includes load side terminals and serves as a functional substitute for older FD3125 breakers. The unit features a trip-free mechanism, visual trip indicator, and HACR certification.

Specifications

Key specifications
Brand Eaton / Cutler-Hammer
Series PDG2
Amperage 125A
Poles 3
Mounting Style Panel Mount
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 3
AIC Rating 65kA @ 240VAC, 35kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC
Fit and installation
Frame Type Complete Breaker
Terminal Type Lugs
For Use With Eaton Power Defense Panelboards, Switchboards, Enclosures
Wire Gauge 4 AWG - 4/0 AWG (Al/Cu)
Max Wire 4/0 AWG
Min Wire 4 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Rotary Handle, Terminal Shields
Accessories Load Terminals (PDG2X3TA225)
Standards CSA C22.2 No. 5, IEC 60947-2, UL 489, RoHS
Approval CCC, CE, CSA, IEC, RoHS, UL
Temp Rating -20C to 70C
Construction Features HACR Rated, RoHS Compliant, Trip-Free Mechanism, Visual Trip Indicator

Product FAQs

8 answers
Does the PDG23G0125TFFL come with line and load lugs?

The "L" suffix in this specific catalog number indicates it includes standard load-side lugs only. The line side is designed to bolt directly to the bus in compatible switchboards or panelboards. Verify your panel connection requirements before installation.

Can this Frame 2 breaker be mounted on a DIN rail?

While the breaker body natively supports bolt-on or panel mounting, it can be easily adapted for DIN rail installations using an official Power Defense Frame 2 DIN rail adapter, such as part number PDG2XDIN75.

Can I use this Power Defense breaker to upgrade an older Series C F-Frame installation?

Yes, the Power Defense Frame 2 (PDG2) series is designed as a direct replacement for legacy Eaton Series C F-Frame and Series G EG-Frame breakers, sharing the same physical footprint for seamless retrofits.

Are the lugs on this breaker interchangeable with legacy Series C F-Frame breakers?

Yes, the Power Defense Frame 2 (PDG2) series is designed to be compatible with legacy Series C F-Frame terminals. You can reuse or swap standard F-Frame lugs and terminals with this modern equivalent.

Is the PDG23G0125TFFL a direct replacement for the obsolete Eaton FD3125?

Yes, this breaker is the modern, drop-in equivalent for the legacy Series C FD3125. It shares the same physical dimensions and provides the identical 35kAIC interrupting capacity at 480VAC.

What does the "TFF" designate in the PDG23G0125TFFL catalog number?

In Eaton's nomenclature, "TFF" indicates a Thermal-Magnetic trip unit with Fixed Thermal and Fixed Magnetic settings. This provides reliable, non-adjustable overcurrent and short-circuit protection.

What is the difference between Eaton's PDG and PDD series circuit breakers?

PDG series breakers (like this unit) are globally rated, carrying UL, CSA, IEC, and CCC certifications for use in systems up to 600VAC. PDD series breakers are domestic, UL-only models limited to 240VAC applications.

Does this breaker feature Arcflash Reduction Maintenance System (ARMS) technology?

No, this specific model is equipped with a basic fixed thermal-magnetic trip unit. ARMS technology is exclusively available on Power Defense circuit breakers equipped with advanced electronic trip units, such as the PXR25.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.