General Electric SKLC3612L5XX 3 Pole Circuit Breaker

ABB / General Electric SKLC3612L5XX - 1200A 3 Pole Molded Case Circuit Breaker

New

$10,031.68 In Stock

Quantity

Similar Items

Description

Designed for demanding industrial applications, the GE SKLC3612L5XX provides 1200A of high-capacity, 3-pole circuit protection. It integrates seamlessly into GE Spectra Series enclosures and is cross-referenced for replacement by the Tmax XT7. Featuring a sophisticated microEntelliGuard electronic trip unit, it offers adjustable Long-Time, Short-Time, Instantaneous, and Ground Fault Alarm (LSIA) functions. This 100% rated breaker ensures reliable 65kAIC protection at 480VAC.

Specifications

Key specifications
Brand ABB / General Electric
Part Number SKLC3612L5XX
Series SKLC
Amperage 1200A
Poles 3
Mounting Style Bolt-On
Voltage 120VAC, 240VAC, 277VAC, 480VAC, 600VAC, 120/240VAC
Phase 3
AIC Rating 100kA @ 120VAC, 100kA @ 240VAC, 65kA @ 277VAC, 65kA @ 480VAC, 42kA @ 600VAC, 100kA @ 120/240VAC
Electrical ratings
Amperage Range 450-1200A
Fit and installation
Frame Type SKLC
Terminal Type Lugs
For Use With GE Spectra Series Panelboards, GE Spectra Series Switchboards, GE Motor Control Centers
Protection and operation
Trip Technology Electronic Trip
Trip Function Code LSIA
Trip Function Long-Time, Short-Time, Instantaneous, Alarm
Trip Adjustability Adjustable
Standards and features
Available Options Lugs, Rating Plugs, Shunt Trip, Auxiliary Switch, Bell Alarm, Undervoltage Release, Padlock Attachment
Accessories No factory-installed accessories
Standards CSA C22.2 No. 5, HACR, IEC 60947-2, UL 489
Approval CE, CSA, IEC, UL
Temp Rating 40C
Construction Features 100% Rated, HACR Rated, Current Limiting, Reverse Feed, True RMS Sensing, Interchangeable Trip Unit

Product FAQs

8 answers
Is the GE SKLC3612L5XX still actively manufactured, or has it been replaced?

This legacy GE Spectra RMS circuit breaker has been officially replaced by the ABB Tmax XT7 series. However, exact replacements are often still available for existing panelboards and switchboards.

Does the SKLC3612L5XX require a rating plug to operate?

Yes, GE Spectra SK1200 frame breakers require a front-mounted rating plug, such as the SRPK1200A1200, to establish the breaker ampere rating and enable the electronic trip unit.

What does the LSIA trip function on this breaker include?

The LSIA electronic trip unit provides adjustable Long-Time, Short-Time, and Instantaneous overcurrent protection, alongside a Ground Fault Alarm. The alarm function alerts operators to ground faults without tripping the breaker.

What equipment is the SKLC3612L5XX compatible with?

This breaker is designed for installation in GE Spectra Series Panelboards, GE Spectra Series Switchboards, and GE Motor Control Centers.

Are lugs included with the SKLC3612L5XX breaker?

Lugs are generally not included with the base breaker frame and must be ordered separately. Compatible lug kits for the SK1200 frame, such as the TCAL124 or TCAL121, accept multiple large-gauge copper or aluminum conductors per phase.

Can the SKLC3612L5XX be reverse fed?

Yes, GE Spectra RMS circuit breakers are suitable for reverse feed applications. They have no line or load markings, allowing incoming power cables or busbars to be connected to either the upper or lower terminals.

Can the trip unit settings be adjusted in the field?

Yes, the integrated microEntelliGuard electronic trip unit features an interface for viewing and changing the various protective function settings in the field to ensure proper system coordination.

What safety precautions should be taken before adjusting the trip unit settings?

Always ensure the breaker is de-energized before installing the rating plug or adjusting the trip unit settings. Incorrect settings can result in a lack of system coordination or inadequate equipment protection.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.