| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124070 |
| Series | TED |
| Amperage | 70A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1/0 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1/0 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Load Side Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124070-R |
| Series | TED |
| Amperage | 70A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1/0 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1/0 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Load Side Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
ABB / General ElectricTED124080
ABB / General ElectricTED124060
ABB / General ElectricTED124090
ABB / General ElectricTED124050
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124070 |
| Series | TED |
| Amperage | 70A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1/0 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1/0 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Load Side Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
This E150 frame breaker is designed for bolt-on installation in GE A-Series and GE Spectra Series panelboards. It occupies two poles of space on the panel bus.
The WL suffix indicates that the circuit breaker is factory-equipped with copper and aluminum compatible line and load lugs. The core breaker specifications remain identical to the standard TED124070.
Both TED and THED breakers share the same physical E150 frame dimensions and panelboard compatibility. However, THED breakers are built with higher interrupting capacity (AIC) ratings and support higher voltage applications up to 600V.
Yes, GE E150 line circuit breakers, including the TED series, are rated for reverse feed installations.
ABB acquired GE Industrial Solutions in 2018. Depending on the production date, these E150 frame breakers may feature either GE or ABB labels. The form, fit, and function are identical regardless of the branding.
Yes, GE TED series molded case circuit breakers carry an HACR rating, making them suitable for heating, air conditioning, and refrigeration applications.
No, this breaker features a non-interchangeable thermal-magnetic trip unit. The long-time and instantaneous protection settings are factory-fixed and cannot be modified in the field.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.