| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124080 |
| Series | TED |
| Amperage | 80A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124080-R |
| Series | TED |
| Amperage | 80A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
ABB / General ElectricTED124090
ABB / General ElectricTED124070
ABB / General ElectricTED124100
ABB / General ElectricTED124060
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124080 |
| Series | TED |
| Amperage | 80A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed |
This bolt-on breaker is designed for installation in legacy GE A-Series and GE Spectra panelboards.
Yes, this breaker is rated for DC applications up to 250VDC with an interrupting capacity of 10kAIC.
Yes, GE TED series molded case circuit breakers are suitable for reverse feed installations.
The factory lugs accept copper or aluminum (Cu/Al) wire ranging from 4 AWG to 3/0 AWG. Always refer to the breaker label for the correct torque specifications during installation.
The LI designation indicates a thermal-magnetic trip unit that provides Long-Time (thermal) protection against overloads and Instantaneous (magnetic) protection against short circuits.
Yes, GE TED series breakers 15A and above are HACR rated for use with heating, air conditioning, and refrigeration equipment.
ABB acquired GE Industrial Solutions. Legacy GE breakers like the TED series are now manufactured and distributed under the ABB brand while maintaining the exact same physical and electrical specifications.
For modern upgrades, the legacy GE E150 line, which includes TED breakers, can often be replaced by the ABB Tmax XT1 series using the appropriate retrofit kits.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.