ABB / General ElectricTED136050
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134050 |
| Series | TED |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release |
|---|---|
| Accessories | Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, HACR, HID, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134050-R |
| Series | TED |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release |
|---|---|
| Accessories | Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, HACR, HID, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Reverse Feed, Non-Interchangeable Trip |
ABB / General ElectricTED136050
ABB / General ElectricTED134045
ABB / General ElectricTED134060
ABB / General ElectricTED136060
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134050 |
| Series | TED |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release |
|---|---|
| Accessories | Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, HACR, HID, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Reverse Feed, Non-Interchangeable Trip |
This bolt-on E-frame breaker installs directly into legacy GE A-Series panelboards, GE Spectra series panels, and compatible GE motor control centers (MCCs) without requiring aftermarket adapter kits.
Yes. ABB acquired GE Industrial Solutions and continues to support legacy catalog numbers. A TED134050 labeled by ABB is electrically and mechanically identical to the original General Electric unit and fits the exact same hardware.
The GE E-150 line, which includes the TED frame, is a legacy product group. For entirely new installations, ABB recommends modern XT2 or Record Plus frames. However, for existing panelboards, sourcing a direct TED134050 replacement is the only way to avoid retrofitting busbars or fabricating custom adapter plates.
Yes. The breaker fits into legacy GE surface or flush-mount enclosures, such as the TE100F and TE100S series. If your installation requires NEMA 12 industrial protection, a separate flange-mounted handle mechanism (like the TDR handle) must be paired with the enclosure.
Yes. The internal thermal-magnetic trip mechanism is fully rated to interrupt DC faults across multiple voltage levels. This makes it a reliable choice for industrial DC control panels, battery backup systems, and specific transit applications requiring an E-frame footprint.
No, the breaker comes equipped with factory-installed load side lugs that accept both copper and aluminum wire. Always reference the manufacturer faceplate for the precise torque specifications during installation to ensure a secure connection and prevent thermal failure.
No. The TED134050 provides standard overload and short-circuit protection using a fixed thermal and magnetic trip unit. If your panel requires a higher-interrupting or current-limiting breaker in the exact same footprint, you must upgrade to the THED frame equivalent.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.