| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134070 |
| Series | TED |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134070 |
| Series | TED |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
ABB / General ElectricTED136070
ABB / General ElectricTED136080
ABB / General ElectricTED134080
ABB / General ElectricTED134060
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134070 |
| Series | TED |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
This E-Frame E-150 line breaker is designed to bolt directly into GE A-Series and GE Spectra panelboards.
Yes, the TED134070 is commonly cross-referenced to the newer TEYD3070B. Before replacing or upgrading, ensure your specific enclosure and mounting hardware will accept the TEYD footprint.
GE uses the WL suffix to indicate that the circuit breaker is shipped from the factory with copper and aluminum line and load side lugs installed. The base breaker body and electrical specifications remain completely identical.
Yes, the E-150 product line, which includes TEB, TED, and THED molded case breakers, features a trip-free mechanism that is fully HACR rated and suitable for reverse feed wiring.
This breaker uses TCAL15 lugs. These terminals accept either copper or aluminum conductors ranging from 4 AWG to a maximum of 3/0 AWG.
Yes, it is fully HACR rated. This makes it approved for use with heating, air conditioning, and refrigeration systems that require reliable multi-motor and combination-load protection.
No. The breaker is built with a fixed thermal-magnetic trip unit and features a non-interchangeable design, meaning the long-time and instantaneous trip functions cannot be modified in the field.
The TED134070 is calibrated for operation in a 40 degrees Celsius (104 degrees Fahrenheit) ambient temperature environment.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.