| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136070-R |
| Series | TED |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 6 AWG - 2/0 AWG (Cu), 4 AWG - 2/0 AWG (Al) |
| Max Wire | 2/0 AWG |
| Min Wire | 6 AWG (Cu), 4 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, 50C Ambient Calibration |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136070-R |
| Series | TED |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 6 AWG - 2/0 AWG (Cu), 4 AWG - 2/0 AWG (Al) |
| Max Wire | 2/0 AWG |
| Min Wire | 6 AWG (Cu), 4 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, 50C Ambient Calibration |
ABB / General ElectricTED134070
ABB / General ElectricTED134080
ABB / General ElectricTED136080
ABB / General ElectricTED134060
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136070-R |
| Series | TED |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 6 AWG - 2/0 AWG (Cu), 4 AWG - 2/0 AWG (Al) |
| Max Wire | 2/0 AWG |
| Min Wire | 6 AWG (Cu), 4 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, 50C Ambient Calibration |
This E-frame breaker is designed for bolt-on installation in legacy GE A-Series and Spectra Series panelboards. It requires a 3-pole space and bolts directly to the panel bus.
ABB acquired GE Industrial Solutions in 2018. Legacy GE molded case circuit breakers, including the TED frame series, are now manufactured and distributed under the ABB brand but retain the exact same physical dimensions and catalog numbers.
Yes, this thermal magnetic breaker is rated for DC systems. It provides a 10kA interrupting capacity at both 250VDC and 500VDC.
The factory installed lugs accept both copper (Cu) and aluminum (Al) conductors. Approved wire ranges are 6 AWG to 2/0 AWG for copper, and 4 AWG to 2/0 AWG for aluminum.
The LI designation means the breaker features Long-Time and Instantaneous trip functions. This is a standard fixed thermal and fixed magnetic protection scheme for general overload and short circuit protection.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.