ABB / General ElectricTED136150WL
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134150WL |
| Series | TED |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134150WL-R |
| Series | TED |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
ABB / General ElectricTED136150WL
ABB / General ElectricTED134125WL
ABB / General ElectricTED136125WL
ABB / General ElectricTED134110WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED134150WL |
| Series | TED |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
The WL suffix designates that the breaker is supplied from the factory with mechanical lugs installed on both the line and load sides, rather than being provided as a bare-terminal breaker for busbar mounting.
ABB acquired General Electric Industrial Solutions. As a result, legacy GE E-frame breakers like the TED series may be shipped with either GE or ABB branding on the front label depending on the manufacturing date, but they are physically and electrically identical.
Breaking higher DC voltages requires more arc-extinguishing capability. To achieve the 500VDC rating, you must wire multiple poles in series according to the manufacturer guidelines. Single-pole interruption at 500VDC will exceed the interrupting capacity of the breaker.
Standard GE TED series thermal-magnetic circuit breakers do not have Line and Load restrictions printed on the faceplate, meaning they are typically suitable for reverse feeding applications. Always verify local code requirements before reverse feeding.
No. This specific breaker features fixed thermal and fixed magnetic trip elements. It does not offer field-adjustable dials for long-time delay, short-time pickup, or instantaneous override functions.
Yes. Because this breaker carries straight voltage ratings (480VAC and 600VAC) rather than a slash rating (like 480Y/277VAC), it is fully rated for phase-to-phase faults on ungrounded, resistance-grounded, or corner-grounded delta systems up to its maximum rated voltage.
No. The LI (Long-Time, Instantaneous) designation means it only provides standard thermal overload and magnetic short-circuit protection. It does not include integral ground fault (LSIG) or earth leakage trip functions.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.