ABB / General ElectricTED134100WL
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136100WL |
| Series | TED |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers, E150 Enclosures |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136100WL-R |
| Series | TED |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers, E150 Enclosures |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
ABB / General ElectricTED134100WL
ABB / General ElectricTED134110WL
ABB / General ElectricTED136110WL
ABB / General ElectricTED134090WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136100WL |
| Series | TED |
| Amperage | 100A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards, Switchboards, Motor Control Centers, E150 Enclosures |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
This E-Frame breaker is designed for use in GE A-Series and Spectra panelboards, as well as compatible switchboards, motor control centers, and E150 enclosures.
It is part of the GE E150 line, commonly referred to as an E-Frame breaker, which supports a maximum continuous current rating of 150 amps.
The WL suffix indicates that the circuit breaker includes factory-installed copper and aluminum line and load lugs. The base TED136100 part number refers to the same breaker body, but the WL confirms the standard lugs are attached.
The included lugs accept 3 AWG to 3/0 AWG copper conductors, or 1 AWG to 3/0 AWG aluminum conductors.
Yes, this breaker is rated for DC applications up to 500VDC. It provides a 10kA interrupting capacity at both 250VDC and 500VDC.
No, this breaker features a non-interchangeable thermal-magnetic trip unit with fixed long-time and fixed instantaneous trip functions. The trip settings cannot be adjusted in the field.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.