ABB / General ElectricTED134100
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136110 |
| Series | TED |
| Amperage | 110A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, Switchboards |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136110 |
| Series | TED |
| Amperage | 110A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, Switchboards |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
ABB / General ElectricTED134100
ABB / General ElectricTED136100
ABB / General ElectricTED134125
ABB / General ElectricTED136125
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136110 |
| Series | TED |
| Amperage | 110A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, Switchboards |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Bell Alarm |
|---|---|
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
The TED136110 is a bolt-on E-frame breaker designed to install directly into GE A-Series panelboards, Spectra Series panelboards, and compatible GE switchboards.
Yes, this thermal-magnetic breaker is rated for DC applications. It provides an interrupting capacity of 10kAIC at both 250VDC and 500VDC, making it suitable for industrial DC control panels and specific solar applications.
The factory lugs on this 110A breaker accept 3 AWG to 3/0 AWG copper wire, or 1 AWG to 3/0 AWG aluminum wire. Ensure conductors are sized appropriately for the 75 degree C temperature rating of the terminals.
Yes, if your system requires a higher fault current rating, the THED136110 is the direct high-interrupting replacement. It shares the same physical E150 footprint but offers up to 65kAIC at 240VAC and 25kAIC at 480VAC.
No, this breaker is equipped with a non-interchangeable, fixed thermal-magnetic trip unit. Both the long-time overload and instantaneous short-circuit trip functions are factory-set and cannot be adjusted in the field.
Yes, GE TEB, TED, and THED series molded case circuit breakers do not have line and load side restrictions, meaning they are fully suitable for reverse feed installations.
ABB acquired GE Industrial Solutions in 2018. As a result, E150 frame breakers like the TED136110 may feature either GE or ABB branding depending on the manufacturing date. The form, fit, and function remain completely identical.
The TED136110 belongs to the GE E150 frame family. This frame size features a 1.375-inch per-pole spacing and is commonly used in commercial lighting and power panelboards.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.