| Brand | ABB / General Electric |
|---|---|
| Part Number | TEY315 |
| Series | TEY |
| Amperage | 15A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 240VAC, 480Y/277VAC, 250VDC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 120VAC, 65kA @ 240VAC, 14kA @ 480Y/277VAC, 10kA @ 250VDC, 65kA @ 120/240VAC |
| Frame Type | TEY |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 14-10 AWG (Cu), 12-10 AWG (Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5.1, UL 489 |
| Approval | CSA, HACR, HID, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEY315-R |
| Series | TEY |
| Amperage | 15A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 240VAC, 480Y/277VAC, 250VDC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 120VAC, 65kA @ 240VAC, 14kA @ 480Y/277VAC, 10kA @ 250VDC, 65kA @ 120/240VAC |
| Frame Type | TEY |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 14-10 AWG (Cu), 12-10 AWG (Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5.1, UL 489 |
| Approval | CSA, HACR, HID, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
ABB / General ElectricTEY315ST12
ABB / General ElectricTEY320ST12
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEY315 |
| Series | TEY |
| Amperage | 15A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 240VAC, 480Y/277VAC, 250VDC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 120VAC, 65kA @ 240VAC, 14kA @ 480Y/277VAC, 10kA @ 250VDC, 65kA @ 120/240VAC |
| Frame Type | TEY |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 14-10 AWG (Cu), 12-10 AWG (Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5.1, UL 489 |
| Approval | CSA, HACR, HID, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
The TEY315 is primarily designed for installation in GE A-Series lighting panelboards, including AQ, AE, AL, and AD types. It features a bolt-on mounting design specific to these enclosures.
Yes. While typically installed directly onto the bus of A-Series panels, this breaker can be adapted for unit-mount or lug-to-lug installations by using a separate GE TEY3B mounting base accessory.
Yes, this breaker is both HACR (Heating, Air Conditioning, and Refrigeration) and HID (High-Intensity Discharge) rated. This makes it compliant for protecting commercial HVAC equipment and specialized lighting circuits.
Yes. In addition to its standard AC ratings, this thermal-magnetic breaker is rated for 250VDC systems, offering a 10kA interrupting capacity for DC distribution applications.
The TEY frame utilizes a compact 1-inch width per pole design. The complete 3-pole TEY315 breaker footprint is exactly 3 inches wide.
Yes. Following ABB's acquisition of GE Industrial Solutions, TEY series breakers may feature either ABB or General Electric branding depending on the date of manufacture. The part numbers, form, fit, and UL listings remain identical.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.