ABB / General ElectricTEYD3025B
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Series | TEYD |
| Amperage | 20A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 250VDC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480Y/277VAC, 10kA @ 250VDC, 65kA @ 120/240VAC |
| Frame Type | TEYD |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 14-10 AWG (Cu), 12-10 AWG (Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Common Trip, Quick-Make/Quick-Break, Visual Trip Indicator, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Series | TEYD |
| Amperage | 20A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 250VDC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480Y/277VAC, 10kA @ 250VDC, 65kA @ 120/240VAC |
| Frame Type | TEYD |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 14-10 AWG (Cu), 12-10 AWG (Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Common Trip, Quick-Make/Quick-Break, Visual Trip Indicator, Non-Interchangeable Trip |
ABB / General ElectricTEYD3025B
ABB / General ElectricTEYD3015B
ABB / General ElectricTEYD3030B
ABB / General ElectricTEYD3035B
| Brand | ABB / General Electric |
|---|---|
| Series | TEYD |
| Amperage | 20A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480Y/277VAC, 250VDC, 120/240VAC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480Y/277VAC, 10kA @ 250VDC, 65kA @ 120/240VAC |
| Frame Type | TEYD |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards |
| Wire Gauge | 14-10 AWG (Cu), 12-10 AWG (Al) |
| Max Wire | 10 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Common Trip, Quick-Make/Quick-Break, Visual Trip Indicator, Non-Interchangeable Trip |
This bolt-on branch breaker is designed specifically for ABB and GE A-Series lighting panelboards. Each pole requires one inch of mounting space within the panel chassis.
These breakers share the exact same physical dimensions and fit the same A-Series panelboards but offer different short-circuit interrupting capacities at 480Y/277VAC. The base TEY provides 14kAIC, the TEYF is 18kAIC, the TEYD is 25kAIC, the TEYH is 35kAIC, and the TEYL provides a maximum 65kAIC.
Yes. This 20-amp model is both HACR rated for heating, air conditioning, and refrigeration systems, and HID rated for switching high-intensity discharge lighting circuits.
Yes. Although it is natively a bolt-on panelboard breaker, it can be adapted for individual lug-to-lug surface mount applications if paired with a separate TEY3B mounting base assembly.
Yes. In addition to its standard commercial AC ratings, this thermal-magnetic breaker is certified for use on up to 250VDC systems, providing a 10kAIC interrupting rating for direct current faults.
No. This unit utilizes standard fixed thermal and magnetic trip elements for traditional overload and short-circuit protection. It does not contain AFCI or GFCI electronics.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.