ABB / General ElectricTFJ236175WL
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFJ236150WL |
| Series | TFJ |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TFJ |
|---|---|
| Terminal Type | Lugs |
| For Use With | Enclosures, Individual Mounting |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFJ236150WL-R |
| Series | TFJ |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TFJ |
|---|---|
| Terminal Type | Lugs |
| For Use With | Enclosures, Individual Mounting |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
ABB / General ElectricTFJ236175WL
ABB / General ElectricTFJ236125WL
ABB / General ElectricTFJ236200WL
ABB / General ElectricTFJ236100WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFJ236150WL-R |
| Series | TFJ |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TFJ |
|---|---|
| Terminal Type | Lugs |
| For Use With | Enclosures, Individual Mounting |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
The "WL" suffix indicates that the circuit breaker comes factory-equipped with line and load terminal lugs. For this model, the included lugs accept 4 AWG to 300 kcmil copper or aluminum wire.
This is a unit-mount circuit breaker designed for individual mounting or installation within compatible enclosures. It is not designed for plug-in or bolt-on panelboard chassis mounting.
The TFJ236150WL features a fixed thermal element for overload protection and an adjustable magnetic element for short-circuit protection. The magnetic trip threshold can be adjusted via a dial on the face of the breaker to coordinate with downstream devices or specific load inrush characteristics.
When applying this thermal-magnetic breaker in DC circuits, ensure the system voltage does not exceed its 500VDC maximum rating. DC applications often require wiring multiple poles in series to safely interrupt the arc, so consult the manufacturer guidelines for proper pole wiring configurations based on your specific DC voltage.
Standard thermal-magnetic molded case circuit breakers without "Line" and "Load" markings are generally suitable for reverse feeding. Always verify the specific labeling on the physical breaker and consult local electrical codes before backfeeding.
ABB acquired GE Industrial Solutions in 2018. As a result, legacy GE molded case circuit breakers like the F-Frame TFJ series are now manufactured and supported under the ABB brand portfolio.
Molded case circuit breakers generally require minimal maintenance. It is recommended to periodically exercise the breaker by manually toggling it on and off, inspect the terminals for proper torque, and ensure the operating environment remains free of excessive dust and moisture.
Yes, as part of the F225 line, this breaker shares the same physical dimensions and mounting footprint as older GE F-Frame units. It can be used as a direct drop-in replacement in existing enclosures or individual mounting setups designed for this frame size.
The LI designation stands for Long-Time and Instantaneous protection. The Long-Time function uses a fixed thermal element to protect against sustained overloads, while the Instantaneous function uses an adjustable magnetic element to clear severe short-circuit faults immediately.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.