ABB / General ElectricTFJ236225WL
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFJ236250WL |
| Series | TFJ |
| Amperage | 250A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Motor Operator |
|---|---|
| Accessories | Includes Line and Load Lugs (TCAL25) |
| Standards | CSA C22.2 No. 5, NEMA AB-1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFJ236250WL-R |
| Series | TFJ |
| Amperage | 250A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Motor Operator |
|---|---|
| Accessories | Includes Line and Load Lugs (TCAL25) |
| Standards | CSA C22.2 No. 5, NEMA AB-1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
ABB / General ElectricTFJ236225WL
ABB / General ElectricTFJ236200WL
ABB / General ElectricTFJ236175WL
ABB / General ElectricTFJ236150WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TFJ236250WL-R |
| Series | TFJ |
| Amperage | 250A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 25kA @ 240VAC, 22kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE A-Series Panelboards, Spectra Series Panelboards, Switchboards, Motor Control Centers, Enclosures |
| Wire Gauge | 4 AWG - 300 kcmil (Cu/Al) |
| Max Wire | 300 kcmil |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Motor Operator |
|---|---|
| Accessories | Includes Line and Load Lugs (TCAL25) |
| Standards | CSA C22.2 No. 5, NEMA AB-1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip |
The "WL" suffix indicates that the circuit breaker ships from the factory with both line and load side lugs installed. These standard factory lugs are rated for terminating either copper or aluminum conductors.
The TFJ series features a factory assembled, non-interchangeable trip unit. In contrast, the TFK series utilizes an interchangeable trip unit, allowing the trip mechanism to be swapped in the field. Both models share the exact same F-Frame physical footprint.
Yes. GE TFJ frame molded case circuit breakers are rated and suitable for reverse feed wiring. Note that the similar TFK frame breakers with interchangeable trips are not suitable for reverse feed.
The TFJ236250WL features a fixed thermal element for standard overload protection and an adjustable magnetic element for short-circuit protection. The instantaneous magnetic pickup levels can be tuned using a dedicated adjustment dial located on the front face of the trip unit.
While the breaker itself is a standard unit mount design, installing it into GE A-Series or Spectra Series panelboards requires specific twin mount hardware kits, such as the AMC or CDP module kits, to securely bolt the breaker to the panelboard bus.
Yes, GE TFJ frame circuit breakers are HACR rated, making them fully compliant and suitable for use with standard heating, air conditioning, and refrigeration equipment group motor loads.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.