| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136070WL |
| Series | THED |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Reverse Feed, Non-Interchangeable Trip, Common Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136070WL-R |
| Series | THED |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Reverse Feed, Non-Interchangeable Trip, Common Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
ABB / General ElectricTHED136080WL
ABB / General ElectricTHED136060WL
ABB / General ElectricTHED136090WL
ABB / General ElectricTHED136050WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136070WL |
| Series | THED |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 4 AWG - 3/0 AWG (Cu/Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 4 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Reverse Feed, Non-Interchangeable Trip, Common Trip, Quick-Make/Quick-Break, Trip-Free Mechanism |
This breaker is part of the legacy General Electric (GE) E-Frame series. Following ABB's acquisition of GE Industrial Solutions, it is now manufactured and supported under the ABB brand.
The "WL" suffix indicates that the circuit breaker comes factory-equipped with copper/aluminum (Cu/Al) line and load lugs.
It belongs to the GE E150 line, commonly referred to as the E-Frame. This frame size supports breakers rated up to 150 amps and 600VAC.
Yes, this breaker is rated for use in DC systems up to 500VDC. It provides a 10kA interrupting capacity at both 250VDC and 500VDC.
The included lugs accept conductor sizes from 4 AWG to 3/0 AWG. They are rated for both copper and aluminum wiring.
This unit-mount, feed-thru breaker is designed for use in compatible GE enclosures, switchboards, and motor control centers that accept E-Frame breakers.
No, this breaker features a fixed thermal-magnetic trip unit. The long-time and instantaneous (LI) protection settings are factory-set and cannot be adjusted in the field.
Yes, standard GE THED series thermal-magnetic breakers are suitable for reverse-feed installations, allowing them to be back-fed when required by the panel configuration.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.