| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136150WL |
| Series | THED |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | UL 489, CSA C22.2 No. 5, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136150WL-R |
| Series | THED |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | UL 489, CSA C22.2 No. 5, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Reverse Feed |
ABB / General ElectricTHED136125WL
ABB / General ElectricTHED136110WL
ABB / General ElectricTHED136100WL
ABB / General ElectricTHED136090WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED136150WL |
| Series | THED |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 18kA @ 600VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | UL 489, CSA C22.2 No. 5, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, High Interrupting Capacity, Reverse Feed |
The WL suffix indicates that the breaker is supplied from the factory with both copper/aluminum line and load lugs included. Breakers in the GE E150 line without this suffix typically come with load-side lugs only.
Yes. GE E150 frame thermal-magnetic breakers, including the TEB, TED, and THED series, are rated for reverse feed installations.
The standard lug terminals on this breaker accept 3 AWG through 3/0 AWG copper wire, or 1 AWG through 3/0 AWG aluminum wire.
This is a unit mount breaker designed for use in GE enclosures, switchboards, and motor control centers that accommodate E150 frame devices. It bolts directly to the mounting pan rather than plugging into a standard panelboard bus.
The THED line is GE's Hi-Break version of the E150 frame. It provides a higher short circuit interrupting capacity, delivering 25kAIC at 480VAC compared to the standard TED series rating of 18kAIC at 480VAC.
No. This breaker is built with a fixed, non-interchangeable thermal-magnetic trip unit. The long-time and instantaneous settings cannot be adjusted, and the trip unit cannot be swapped for a different amperage rating.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.