ABB / General ElectricTHHQB32045
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THHQB32040 |
| Series | THHQB |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC |
| Frame Type | THQB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE A-Series Panelboards, GE AQ Lighting Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Padlock Attachment |
|---|---|
| Accessories | None included |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip, Reverse Feed, High Interrupting Capacity |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THHQB32040-R |
| Series | THHQB |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC |
| Frame Type | THQB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE A-Series Panelboards, GE AQ Lighting Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Padlock Attachment |
|---|---|
| Accessories | None included |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip, Reverse Feed, High Interrupting Capacity |
ABB / General ElectricTHHQB32045
ABB / General ElectricTHHQB32050
ABB / General ElectricTHHQB32030
ABB / General ElectricTHHQB32025
| Brand | ABB / General Electric |
|---|---|
| Part Number | THHQB32040 |
| Series | THHQB |
| Amperage | 40A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC |
| Frame Type | THQB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE A-Series Panelboards, GE AQ Lighting Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Padlock Attachment |
|---|---|
| Accessories | None included |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip, Reverse Feed, High Interrupting Capacity |
The THHQB32040 is a bolt-on breaker designed specifically for installation in GE A-Series panelboards and GE AQ lighting panels.
Yes. The THHQB32040 shares the same physical dimensions and bolt-on mounting as the THQB32040, but offers a higher interrupting rating of 22kAIC compared to the standard 10kAIC. It is a direct upgrade for systems requiring higher fault current protection.
The box lug terminals on this breaker are rated to accept 8 AWG through 3 AWG wire. They are compatible with both copper and aluminum conductors.
Yes, this circuit breaker is HACR rated, meaning it is certified for safe use with heating, air conditioning, and refrigeration equipment.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.