Providing superior circuit protection, the Square D HJA260201 2-pole, 20A molded case circuit breaker features fixed thermal and adjustable magnetic trip settings for precise LI protection. Designed specifically for Square D I-Line panelboards and switchboards, this unit comes factory-configured with a phase AB connection. It easily replaces discontinued FH26020 breakers. With a high 65kAIC interrupting rating at 480VAC, this current-limiting breaker supports reverse feeding.
Can the HJA260201 replace older Square D circuit breakers?
Yes, the PowerPacT H-frame series can serve as an alternative solution for legacy Square D F-frame breakers. Specifically, the HJA260201 easily replaces discontinued 2-pole, 20A I-Line breakers like the FH26020, maintaining the same mounting space in your panelboard.
What equipment is compatible with the HJA260201?
This breaker is designed exclusively for use in Square D I-Line panelboards and switchboards. It is not compatible with standard unit-mount or load center applications.
How does the I-Line connection on this breaker work?
The HJA260201 features a plug-on design for the line side, allowing it to snap directly onto the bus of a Square D I-Line panelboard or switchboard. The load side utilizes standard mechanical lugs for your outgoing wire connections.
What is the recommended lug torque for the HJA260201?
The standard AL150HD load-side mechanical lugs require specific torque settings based on your wire size. For example, 14 AWG to 10 AWG conductors should be torqued to 44.25 lb-in (5 N.m). Always verify the exact torque specifications printed on the breaker label for larger wire sizes before terminating.
What does the J in the HJA260201 catalog number indicate?
The J designates the interrupting capacity level of the PowerPacT H-frame breaker. For this model, it indicates a high interrupting rating of 100kA at 240VAC, 65kA at 480VAC, and 25kA at 600VAC.
What phase configuration does the HJA260201 use?
This specific 2-pole I-Line circuit breaker comes factory-configured for an AB phase connection on the panelboard bus.
What type of protection does the LI trip function provide?
The thermal-magnetic trip unit provides Long-Time (L) protection against sustained overloads using a fixed thermal element, and Instantaneous (I) protection against short circuits using an adjustable magnetic element.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 4.7 out of 5 based on 15 reviews.