Built for heavy-duty commercial use, the Square D HLA36080 is an 80A, 3-pole MCCB in the PowerPacT H-Frame series. It delivers long-time and instantaneous (LI) protection with an adjustable magnetic trip. The breaker utilizes an I-Line plug-on mounting connection, designed specifically to fit Square D I-Line panelboards and switchboards. With a high interrupting capacity of 100kA at 480VAC, this current-limiting device ensures superior fault protection and features a Visi-Trip indicator.
Which panelboards are compatible with the HLA36080?
This I-Line breaker is designed exclusively for use in Square D I-Line panelboards and I-Line switchboards. It uses a plug-on jaw connection to mount directly to the interior bus assembly.
Can the HLA36080 replace older Square D F-frame I-Line circuit breakers?
Yes, PowerPacT H-frame I-Line breakers like the HLA36080 are the modern replacements for older 3-pole legacy F-frame breakers, such as the FA, FH, and FC series. Because both frame types require 4.5 inches of bus space, the HLA36080 can serve as a direct drop-in retrofit.
Is the HLA36080 an exact replacement for the FHL36080?
While it will fit the exact same panel space, the HLA36080 offers a much higher interrupting capacity (100kA at 480VAC) compared to the legacy FHL36080 (25kA at 480VAC). It is a suitable physical replacement that provides a significant upgrade in short-circuit protection.
What does the "L" in the HLA part number signify?
The "L" indicates the interrupting rating tier of the breaker. Within the PowerPacT H-frame family, the L-tier provides up to 100kA of interrupting capacity at 480VAC. Other available tiers include D (18kA), G (35kA), and J (65kA).
How is the HLA36080 physically installed into the panel?
The line side features plug-on jaws that push directly onto the panelboard's vertical bus bars. The breaker is then physically secured to the panel interior using a captive mounting bracket and screw.
Can the HLA36080 be reverse-fed?
No. I-Line circuit breakers cannot be reverse-fed. The line side connection is a fixed, plug-on jaw assembly designed exclusively to receive power from the panelboard bus, meaning power must flow from line to load.
What are the magnetic hold and trip thresholds for this 80A breaker?
The factory magnetic settings for the 80A HLA36080 include a hold current of 800A and a maximum magnetic trip threshold of 1450A.
Are the load side lugs on the HLA36080 field-replaceable?
Yes, the standard AL150HD mechanical lugs on the load side can be removed to accommodate optional compression lugs, distribution blocks, or copper-only lugs (such as the CU150HD) if your installation requires them.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 1 review.