Engineered for industrial applications, the Square D HLA36090 is a 3-pole, 90A PowerPacT H-Frame molded case circuit breaker. It provides reliable thermal-magnetic protection with fixed long-time and instantaneous (LI) trip functions. Featuring a robust I-Line mounting style, this unit installs into compatible Square D I-Line panelboards and switchboards. Rated for 100kAIC at 480VAC, it offers exceptional fault current limitation and includes a Visi-Trip indicator for quick status checks.
CSA C22.2 No. 5, HACR, IEC 60947-2, NEMA AB 1, UL 489
Approval
CE, CSA, IEC, NOM, UL
Temp Rating
-25C to 70C
Construction Features
HACR Rated, Current Limiting, Reverse Feed, Non-Interchangeable Trip
Product FAQs
7 answers
What panelboards and switchboards are compatible with the HLA36090?
This breaker is designed for use in Square D I-Line panelboards and switchboards. It features an I-Line style plug-in connection for the line side and mechanical lugs on the load side.
Can the PowerPacT HLA36090 replace older F-frame I-Line breakers?
Yes, the PowerPacT H-frame is the modern replacement for legacy 90-amp F-frame I-Line breakers, such as the FA, FH, and FC series. The H-frame offers higher interrupting ratings and supports field-installable accessories while fitting the same I-Line bus footprint.
What does the L in the HLA36090 catalog number indicate?
The L designates the interrupting rating level of the PowerPacT H-frame breaker. It indicates a high interrupting capacity of 125kA at 240VAC, 100kA at 480VAC, and 50kA at 600VAC.
Are the trip settings adjustable on the HLA36090?
No, this breaker features a thermal magnetic trip unit with fixed thermal and fixed magnetic settings. It provides standard long-time and instantaneous protection.
What wire sizes are accepted by the lugs on the HLA36090?
The standard factory-installed AL150HD load-side lugs accept 14 AWG to 3/0 AWG aluminum or copper conductors.
What are the torque specifications for the load-side lugs on this breaker?
For the standard AL150HD lugs, the tightening torque is 44 lbf-in (5 N.m) for 14 to 10 AWG wire, and 124 lbf-in (14 N.m) for 8 to 3/0 AWG wire.
What safety precautions should be taken before installing this I-Line breaker?
Always de-energize the I-Line panelboard or switchboard before installing or servicing the breaker. Verify that the power is off using a properly rated voltage sensing device, and wear appropriate personal protective equipment in compliance with NFPA 70E.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.