Providing reliable branch circuit protection, the QOB215 handles commercial and industrial loads with a standard 10kA interrupting rating. This two-pole unit mounts securely into Square D NQ and legacy NQOD panelboards using a bolted connection, ensuring a tight fit in high-vibration environments. Electricians appreciate the signature Visi-Trip red indicator flag, which makes spotting a tripped circuit fast and simple during routine facility maintenance or unexpected power outages.
Square D NQ Panelboards, Square D NQOD Panelboards
Wire Gauge
14-8 AWG (Cu/Al)
Max Wire
8 AWG
Min Wire
14 AWG
Protection and operation
Trip Technology
Thermal Magnetic
Trip Function Code
LI
Trip Function
Long-Time, Instantaneous
Trip Adjustability
Fixed
Standards and features
Available Options
Padlock Attachment
Accessories
Load Side Lugs Included
Standards
CSA C22.2 No. 5, HACR, UL 489
Approval
CSA, HACR, UL
Temp Rating
40C
Construction Features
HACR Rated, Visual Trip Indicator
Product FAQs
8 answers
Can I install the QOB215 in a standard residential QO load center?
No. The QOB215 features a bolt-on connection designed specifically for commercial Square D NQ and NQOD panelboards. Standard residential QO load centers require plug-on breakers and lack the tapped busbars needed for a bolt-on installation.
What is the difference between the QO215 and the QOB215?
The primary difference is the mounting method. The QO215 is a plug-on breaker used in standard load centers, while the QOB215 is a bolt-on breaker used in commercial panelboards. Both models share the same 15-amp, 2-pole thermal-magnetic trip characteristics.
Does the QOB215 replace older Square D Q1B breakers?
Yes. The QOB series is the direct factory replacement for obsolete Q1B bolt-on branch breakers originally installed in older NQO and NQOB panelboards.
What does the LI trip function mean on this breaker?
The LI designation means the breaker's thermal-magnetic trip unit includes Long-time and Instantaneous protection. The Long-time (thermal) function handles sustained overloads and allows temporary motor inrushes without nuisance tripping, while the Instantaneous (magnetic) function trips immediately during high-current short circuits.
Can the QOB215 be used in direct current (DC) applications?
Yes. In addition to its AC ratings, the QOB215 is rated for up to 48VDC with an interrupting capacity of 5kA. This makes it suitable for low-voltage DC distribution or industrial control circuits requiring a bolt-on form factor.
How should conductors be terminated to the QOB215?
Strip the copper or aluminum conductor and insert it into the pressure plate terminal, which accepts wire sizes from 14 AWG to 8 AWG. Always tighten the terminal screw to the exact torque value printed on the side of the breaker to ensure a safe, NEC-compliant connection.
Is the QOB215 circuit breaker HACR rated?
Yes. Like most standard Square D QO and QOB circuit breakers, the QOB215 is HACR rated, meaning it is approved for use with heating, air conditioning, and refrigeration equipment.
How does the Visi-Trip indicator function on the QOB215?
When the breaker trips due to an overload or short circuit, the handle snaps to a midpoint position and a highly visible red indicator appears in a window on the breaker face. This safety feature allows you to quickly identify the tripped breaker in a fully populated panelboard.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 4.9 out of 5 based on 205 reviews.
4.9
Rated 4.9 out of 5 stars
Based on 205 reviews
5
Rated out of 5 stars
197
4
Rated out of 5 stars
6
3
Rated out of 5 stars
1
2
Rated out of 5 stars
0
1
Rated out of 5 stars
1
Reviews Summary
Generated by AI from 100 most recent customer reviews
Last updated 3/11/26
Customers say these electrical breakers arrive exactly as ordered and work perfectly for their intended applications. They consistently praise the competitive pricing, which many report is significantly lower than local suppliers. Fast shipping and prompt delivery are frequently highlighted, with many receiving orders within days or even next-day delivery for urgent needs. The breakers arrive well-packaged and in excellent condition. Many reviews emphasize the company's extensive inventory availability, particularly for hard-to-find breakers. One customer experienced difficulty with order cancellation and was charged a restocking fee, which caused dissatisfaction.