| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL21125 |
| Series | THQL |
| Amperage | 125A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE Q-Line Load Centers, Lighting Panels |
| Wire Gauge | 2-2/0 AWG (Cu/Al) |
| Max Wire | 2/0 AWG |
| Min Wire | 2 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Padlock Attachment |
|---|---|
| Standards | HACR, UL 489 |
| Approval | UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL21125-R |
| Series | THQL |
| Amperage | 125A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE Q-Line Load Centers, Lighting Panels |
| Wire Gauge | 2-2/0 AWG (Cu/Al) |
| Max Wire | 2/0 AWG |
| Min Wire | 2 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Padlock Attachment |
|---|---|
| Standards | HACR, UL 489 |
| Approval | UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break |
ABB / General ElectricTHQL21WY20
ABB / General ElectricTQD22125
ABB / General ElectricTQD22125WL
ABB / General ElectricTHQD22125WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL21125 |
| Series | THQL |
| Amperage | 125A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE Q-Line Load Centers, Lighting Panels |
| Wire Gauge | 2-2/0 AWG (Cu/Al) |
| Max Wire | 2/0 AWG |
| Min Wire | 2 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Padlock Attachment |
|---|---|
| Standards | HACR, UL 489 |
| Approval | UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break |
This breaker is designed for use in GE PowerMark Gold and PowerMark Plus load centers, as well as compatible AL series lighting panels that accept Q-Line plug-in breakers.
THQL breakers are standard 1-inch per pole breakers, while THQP are 1/2-inch half-size breakers. You can only use the THQL21125 if your panel label explicitly lists THQL as an approved breaker type and has two full 1-inch spaces available.
As a 2-pole THQL series breaker, it requires two standard 1-inch spaces, taking up a total of 2 inches on the panel bus.
Yes, it can be used as a back-fed main breaker in compatible main lug load centers. However, it requires a separate hold-down kit, such as the THQLRK retainer bracket, to comply with National Electrical Code (NEC) requirements.
Yes, this breaker is HACR rated, making it suitable for use with heating, air conditioning, and refrigeration equipment that requires this specific listing.
The LI designation indicates that the thermal-magnetic trip unit provides both Long-Time (thermal) protection against sustained overloads and Instantaneous (magnetic) protection against short circuits.
Yes. Following ABB acquiring GE Industrial Solutions, these breakers are manufactured to the exact same specifications and are fully interchangeable. The product may arrive with either ABB or GE branding.
Yes, the THQL21125 is the direct replacement for older GE 125A 2-pole Q-Line breakers, including older TQL and THQ models with the same amperage and voltage ratings.
No, the THQL21125 is a standard thermal-magnetic circuit breaker. It does not provide Ground Fault Circuit Interrupter (GFCI) or Arc Fault Circuit Interrupter (AFCI) protection.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.