| Brand | ABB / General Electric |
|---|---|
| Part Number | TJD432300WL |
| Series | TJD |
| Amperage | 300A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC, 20kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE J-Frame Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | (1) 6 AWG - 600 kcmil or (2) 2/0 AWG - 250 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Undervoltage Release, Auxiliary Switch, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs (TCAL43) |
| Standards | UL 489, NEMA AB-1, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Non-Interchangeable Trip, Common Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TJD432300WL-R |
| Series | TJD |
| Amperage | 300A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC, 20kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE J-Frame Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | (1) 6 AWG - 600 kcmil or (2) 2/0 AWG - 250 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Undervoltage Release, Auxiliary Switch, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs (TCAL43) |
| Standards | UL 489, NEMA AB-1, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Non-Interchangeable Trip, Common Trip |
ABB / General ElectricTJD432350WL
ABB / General ElectricTJD432250WL
ABB / General ElectricTJD432400WL
ABB / General ElectricTJD432300
| Brand | ABB / General Electric |
|---|---|
| Part Number | TJD432300WL |
| Series | TJD |
| Amperage | 300A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 250VDC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC, 20kA @ 250VDC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE J-Frame Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | (1) 6 AWG - 600 kcmil or (2) 2/0 AWG - 250 kcmil (Cu/Al) |
| Max Wire | 600 kcmil |
| Min Wire | 6 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Undervoltage Release, Auxiliary Switch, Alarm Switch |
|---|---|
| Accessories | Line and Load Lugs (TCAL43) |
| Standards | UL 489, NEMA AB-1, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | Non-Interchangeable Trip, Common Trip |
Yes. Following ABB's acquisition of GE Industrial Solutions, this J-Frame circuit breaker may be branded as either GE or ABB. The physical dimensions, fit, and electrical specifications remain identical regardless of the brand label.
The WL suffix indicates that the circuit breaker comes factory-equipped with both line and load side aluminum/copper lugs. If your application does not require line lugs, the base product number without the WL is used.
This 300A breaker is designed to mount in GE J600 panelboards, switchboards, and motor control centers. It is also compatible with standalone GE J-Frame enclosures, such as the NEMA 1 rated TJ400S surface-mount enclosure.
The included line and load lugs accept either one conductor from 6 AWG to 600 kcmil, or two conductors from 2/0 AWG to 250 kcmil. The terminals are rated for both copper and aluminum wiring.
The GE TJD series has entered the limited phase of its product life cycle. For new installations or direct replacements where the legacy TJD frame is unavailable, ABB recommends the Tmax XT5 series molded case circuit breakers as the modern alternative.
No. This breaker is equipped with a fixed thermal and fixed magnetic trip unit. It provides standard long-time and instantaneous (LI) protection functions that cannot be adjusted in the field.
Yes. In addition to its 240VAC rating, this breaker is rated for 250VDC applications with an interrupting capacity of 20kA.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.