Eaton / Cutler-HammerFAZ-B15/3-NA
Quantity
New
Quantity
Eaton / Cutler-HammerFAZ-B15/3-NA
Eaton / Cutler-HammerFAZ-B30/3-NA
Eaton / Cutler-HammerFAZ-C32/3-NA
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | FAZ-D1/3-NA |
| Series | FAZ |
| Amperage | 1A |
| Poles | 3 |
| Mounting Style | DIN Rail |
| Voltage | 480Y/277VAC, 96VDC |
| Phase | 3 |
| AIC Rating | 10kA @ 480Y/277VAC, 10kA @ 96VDC |
| Frame Type | FAZ |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | DIN Rail Systems, Industrial Control Panels |
| Wire Gauge | 18-6 AWG |
| Max Wire | 6 AWG |
| Min Wire | 18 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Curve | D |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Auxiliary Switch, Shunt Trip, Undervoltage Release, Lockout Attachment, Busbar System |
|---|---|
| Standards | CSA C22.2 No. 5, IEC 60947-2, UL 489 |
| Approval | ABS, CE, CSA, IEC, RoHS, UL, VDE |
| Temp Rating | -25C to 75C |
| Construction Features | HACR Rated, Current Limiting, Trip-Free Mechanism, Visual Trip Indicator, Finger-Safe Terminals, Reverse Feed |
The D curve indicates a magnetic trip point between 10 and 20 times the rated current. This makes it ideal for highly inductive loads with significant inrush currents, such as motors, transformers, and power supplies, preventing nuisance tripping during startup.
Yes, the -NA suffix designates this breaker as UL 489 listed for branch circuit protection. It can be used in applications where UL 1077 supplementary protectors are allowed, but it provides full branch circuit protection for industrial control panels and feeder circuits.
This miniature circuit breaker snaps directly onto a standard 35mm DIN rail. It features a trip-free design and can be fed from either the line or load side for flexible panel wiring.
Yes, this breaker is current limiting. It interrupts fault currents within one half cycle, which significantly reduces the peak let-through energy and provides superior protection for downstream circuit components.
The breaker includes a color-coded visual position indicator on the front face. It displays red when the contacts are closed (ON) and green when the contacts are open (OFF), ensuring safe isolation verification.
Yes, this breaker is dual-rated for both AC and DC applications. It supports up to 96VDC with a 10kA interrupting rating, making it suitable for various control instrumentation and DC power supply circuits.
This model comes equipped with standard box lug terminals that accept conductors ranging from 18 AWG to 6 AWG. The captive screw design ensures the terminal screws cannot be lost during installation or maintenance.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.