| Brand | ABB / General Electric |
|---|---|
| Series | TED |
| Amperage | 50A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Lug Kits |
|---|---|
| Accessories | Load Lugs (TCAL12) |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CE, CSA, UL |
| Temp Rating | 50C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, 50C Ambient Calibration |
Yes. Both breakers share the exact same physical dimensions, bolt-on mounting, and E-frame footprint. The only difference is the TED134C5050 is calibrated for a 50 degrees Celsius ambient temperature, making it a direct replacement that is better suited for hot environments.
The C suffix designates that the thermal trip unit is calibrated for a 50 degrees Celsius ambient temperature, rather than the standard 40 degrees Celsius calibration found on standard GE E150 line breakers.
Yes. GE TED series thermal magnetic circuit breakers do not have dedicated line and load side restrictions, making them fully suitable for reverse feed installations.
Yes. GE E150 line molded case circuit breakers, including the TED frame, are HACR rated for use with heating, air conditioning, and refrigeration equipment.
No. This E-frame breaker features fixed thermal and fixed magnetic trip elements. If your application requires adjustable long-time or instantaneous pickup settings, you will need to specify a breaker with an electronic trip unit, such as the GE Spectra RMS series.
ABB acquired GE Industrial Solutions in 2018. Depending on the manufacturing date, the TED134C5050 you receive may feature either ABB or GE branding. The physical footprint, specifications, and UL listings remain identical regardless of the label.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.