| Brand | ABB / General Electric |
|---|---|
| Part Number | TQDL21175 |
| Series | TQDL |
| Amperage | 175A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE PowerMark Gold Load Centers, GE PowerMark Plus Load Centers, ABB ReliaHome Load Centers |
| Wire Gauge | 1/0 AWG - 250 kcmil (Cu/Al) |
| Max Wire | 250 kcmil |
| Min Wire | 1/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | Lugs |
| Standards | UL 489 |
| Approval | HACR, UL |
| Temp Rating | 60C/75C |
| Construction Features | Common Trip, HACR Rated, Quick-Make/Quick-Break, Trip-Free Mechanism |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TQDL21175-R |
| Series | TQDL |
| Amperage | 175A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE PowerMark Gold Load Centers, GE PowerMark Plus Load Centers, ABB ReliaHome Load Centers |
| Wire Gauge | 1/0 AWG - 250 kcmil (Cu/Al) |
| Max Wire | 250 kcmil |
| Min Wire | 1/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | Lugs |
| Standards | UL 489 |
| Approval | HACR, UL |
| Temp Rating | 60C/75C |
| Construction Features | Common Trip, HACR Rated, Quick-Make/Quick-Break, Trip-Free Mechanism |
ABB / General ElectricTQDL21200
ABB / General ElectricTQDL21150
ABB / General ElectricTQDL21125
ABB / General ElectricTQD22175
| Brand | ABB / General Electric |
|---|---|
| Part Number | TQDL21175 |
| Series | TQDL |
| Amperage | 175A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | GE PowerMark Gold Load Centers, GE PowerMark Plus Load Centers, ABB ReliaHome Load Centers |
| Wire Gauge | 1/0 AWG - 250 kcmil (Cu/Al) |
| Max Wire | 250 kcmil |
| Min Wire | 1/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | Lugs |
| Standards | UL 489 |
| Approval | HACR, UL |
| Temp Rating | 60C/75C |
| Construction Features | Common Trip, HACR Rated, Quick-Make/Quick-Break, Trip-Free Mechanism |
The TQDL21175 is designed for plug-on installation in GE PowerMark Gold, GE PowerMark Plus, and ABB ReliaHome load centers. Always verify compatibility with your specific panel's labeling before installation.
As a double-wide Q-Line breaker, the TQDL21175 requires four standard 1-inch panel spaces arranged in a 2x2 configuration in compatible GE and ABB load centers.
The load-side lugs on this breaker accept copper or aluminum wire ranging from 1/0 AWG to 250 kcmil. Ensure proper torque specifications are followed during installation.
Both are 175A, 2-pole plug-on circuit breakers with the same physical dimensions, but they have different interrupting ratings. The TQDL21175 is rated for 10kAIC, while the THQDL21175 is a higher-rated version designed for systems requiring a 22kAIC interrupting capacity.
Yes. Following ABB's acquisition of GE Industrial Solutions, these breakers may be branded as either ABB or GE. The product itself remains identical in form, fit, function, and specifications regardless of the label.
Yes, this 2-pole breaker features an internal common trip mechanism, ensuring that an overcurrent or short circuit on either pole will simultaneously disconnect both legs of the circuit.
Yes, TQDL frame breakers are HACR rated, making them suitable for use with heating, air conditioning, and refrigeration equipment that requires this specific certification.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.