ABB / General ElectricTQDL21125
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TQDL21150 |
| Series | TQDL |
| Amperage | 150A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | TQDL |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE PowerMark Gold Load Centers, GE PowerMark Plus Load Centers, ABB ReliaHome Load Centers |
| Wire Gauge | 1/0 AWG - 250 kcmil (Cu/Al) |
| Max Wire | 250 kcmil |
| Min Wire | 1/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | Lugs |
| Standards | UL 489 |
| Approval | HACR, UL |
| Temp Rating | 60C/75C |
| Construction Features | Common Trip, HACR Rated, Quick-Make/Quick-Break, Trip-Free Mechanism |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TQDL21150-R |
| Series | TQDL |
| Amperage | 150A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | TQDL |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE PowerMark Gold Load Centers, GE PowerMark Plus Load Centers, ABB ReliaHome Load Centers |
| Wire Gauge | 1/0 AWG - 250 kcmil (Cu/Al) |
| Max Wire | 250 kcmil |
| Min Wire | 1/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | Lugs |
| Standards | UL 489 |
| Approval | HACR, UL |
| Temp Rating | 60C/75C |
| Construction Features | Common Trip, HACR Rated, Quick-Make/Quick-Break, Trip-Free Mechanism |
ABB / General ElectricTQDL21125
ABB / General ElectricTQDL21200
ABB / General ElectricTQD22150
ABB / General ElectricTQD22150WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TQDL21150-R |
| Series | TQDL |
| Amperage | 150A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | TQDL |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE PowerMark Gold Load Centers, GE PowerMark Plus Load Centers, ABB ReliaHome Load Centers |
| Wire Gauge | 1/0 AWG - 250 kcmil (Cu/Al) |
| Max Wire | 250 kcmil |
| Min Wire | 1/0 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment |
|---|---|
| Accessories | Lugs |
| Standards | UL 489 |
| Approval | HACR, UL |
| Temp Rating | 60C/75C |
| Construction Features | Common Trip, HACR Rated, Quick-Make/Quick-Break, Trip-Free Mechanism |
This plug-on breaker is approved for use in GE PowerMark Gold, GE PowerMark Plus, and ABB ReliaHome load centers. Because it utilizes the double-wide QD frame, you must have four standard 1-inch spaces available in a 2x2 configuration to install it.
The breaker lugs accept copper or aluminum wiring from 1/0 AWG to 250 kcmil. When installing aluminum conductors, electricians should apply a listed joint compound to prevent oxidation. Always verify the correct torque settings printed directly on the breaker label prior to energizing.
Yes. The TQDL21150 has a 10kAIC fault rating, while the THQDL21150 is the high-interrupting version rated at 22kAIC. They share the same physical dimensions, so the THQDL21150 can serve as a direct, upgraded substitute if your facility requires a higher interrupting capacity.
Yes, the TQDL21150 carries a HACR rating, making it UL approved to protect dedicated circuits for heavy-duty heating, air conditioning, and refrigeration equipment.
Yes. The breaker is built with an internal common trip mechanism. An overload or short circuit detected on one leg will force both poles to open simultaneously, safely disconnecting all power to the 240V load.
Depending on the specific load center configuration and the required retaining hardware, this Q-Line molded case breaker can function either as a main breaker or a large branch feeder for subpanels and heavy commercial loads.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.