Eaton / Cutler-HammerBAB3015HS
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3015H |
| Series | BAB |
| Amperage | 15A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards |
| Wire Gauge | 14-8 AWG (Al/Cu) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Standards | HACR, UL 489, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3015H-R |
| Series | BAB |
| Amperage | 15A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards |
| Wire Gauge | 14-8 AWG (Al/Cu) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Standards | HACR, UL 489, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Eaton / Cutler-HammerBAB3015HS
Eaton / Cutler-HammerBAB3020HS
Eaton / Cutler-HammerBAB3020HS1
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3015H |
| Series | BAB |
| Amperage | 15A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards |
| Wire Gauge | 14-8 AWG (Al/Cu) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Undervoltage Release, Padlock Attachment, Handle Lock |
|---|---|
| Standards | HACR, UL 489, CSA C22.2 No. 5 |
| Approval | CSA, UL |
| Temp Rating | 40C |
The BAB3015H mounts in Eaton Pow-R-Line 1 (PRL1a) panelboards. It is also compatible with legacy Westinghouse and Cutler-Hammer bolt-on load centers and panelboards designed for BAB series breakers. It will not fit in PRL2a panels, which require GHB series breakers.
Yes, all Eaton BAB circuit breakers from 15A to 100A are HACR rated. This makes the BAB3015H suitable for group motor applications in heating, air conditioning, and refrigeration equipment.
Yes, the BAB3015H is the direct replacement for the legacy Westinghouse and Cutler-Hammer BAB3015. The "H" suffix is Eaton's modern catalog designation for their 3-pole, straight 240V BAB breakers.
The box lugs on the BAB3015H require 20 lb-in of torque for 14-10 AWG conductors, and 25 lb-in for 8 AWG conductors. Always verify torque values on the physical breaker label before terminating.
Because it carries a straight 240V maximum rating rather than a slash rating, the BAB3015H can be safely applied across 208Y/120V Wye, 240/120V High-Leg Delta, and 3-wire 240V Delta systems.
No, the BAB3015H is not SWD rated. Switching Duty ratings for fluorescent lighting applications only apply to the 15A and 20A single-pole breakers in the BAB family.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.