| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3070H |
| Series | BAB |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards, Challenger Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3070H-R |
| Series | BAB |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards, Challenger Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
Eaton / Cutler-HammerBAB3070HS
Eaton / Cutler-HammerBAB3080HS
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | BAB3070H |
| Series | BAB |
| Amperage | 70A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 10kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards, Cutler-Hammer Panelboards, Bryant Panelboards, Challenger Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
This bolt-on miniature breaker mounts directly into Eaton Pow-R-Line load centers, specifically the PRL1a, PRL2a, PRL3a, and PRL4a series panelboards.
Yes. Eaton currently manufactures the Quicklag BAB series to be fully backwards compatible with older bolt-on load centers originally branded by Westinghouse, Cutler-Hammer, Bryant, and Challenger.
The H designation signifies a maximum voltage rating of 240V AC. This allows the breaker to be safely used on 240V Delta or 208Y/120V 3-phase systems, whereas standard non-H models are restricted to 120/240V applications.
Yes, Eaton Quicklag BAB circuit breakers up to 100 amps are HACR rated. This certification ensures the breaker can safely handle the inrush currents of heating, air conditioning, and refrigeration motor loads.
Both series share the identical Quicklag bolt-on footprint, but they have different interrupt ratings. The BAB3070H is rated at 10kAIC, while the QBHW series is rated at 22kAIC. Only substitute the BAB3070H if your system's available fault current is safely below 10,000 amps.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.