| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | QBHW3090H |
| Series | QBHW |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | QBHW3090H-R |
| Series | QBHW |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip |
Eaton / Cutler-HammerQBHW3100H
Eaton / Cutler-HammerQBHW3070H
Eaton / Cutler-HammerQBHW3060H
Eaton / Cutler-HammerQBHW3050H
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | QBHW3090H |
| Series | QBHW |
| Amperage | 90A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton Pow-R-Line Panelboards, Westinghouse Panelboards |
| Wire Gauge | 8-1/0 AWG (Cu/Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip |
This bolt-on breaker is designed for use in Eaton Pow-R-Line panelboards and legacy Westinghouse panelboards that accept Quicklag B-frame breakers.
Both are 90-amp, 3-pole bolt-on breakers with the same physical dimensions, but they have different interrupting ratings. The QBHW3090H has a 22kAIC rating at 240VAC, whereas the BAB series is rated for 10kAIC.
Yes. Eaton acquired the Westinghouse distribution equipment line, so the current Eaton Cutler-Hammer QBHW3090H is the direct replacement for the older Westinghouse version with the same catalog number.
Yes, this breaker is HACR rated, making it suitable and safe for use with heating, air conditioning, and refrigeration equipment.
Bolt-on breakers provide a secure, mechanically fastened connection to the panelboard bus bar. This prevents the breaker from loosening over time due to vibrations or thermal cycling, which is why they are often required in commercial and industrial environments.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.