Eaton / Cutler-HammerQCGFEP1020
Quantity
New
Quantity
Eaton / Cutler-HammerQCGFEP1020
Eaton / Cutler-HammerQCGFEP1015
Eaton / Cutler-HammerQCGFEP2030
Eaton / Cutler-HammerQBGFEP1030
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | QCGFEP1030 |
| Series | QCGFEP |
| Amperage | 30A |
| Poles | 1 |
| Mounting Style | Panel Mount |
| Voltage | 120VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120VAC |
| Frame Type | QCGF |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | Eaton Quicklag Panelboards, Quicklag Enclosures |
| Wire Gauge | 14-4 AWG |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFEP |
|---|---|
| Available Options | Padlock Attachment, DIN Rail Adapter |
| Accessories | Line and Load Lugs Included |
| Standards | CSA C22.2 No. 5, UL 1053, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, 30mA Trip Sensitivity |
The QCGFEP1030 is a Ground Fault Equipment Protector (GFEP) with a 30mA trip threshold, designed to protect equipment from damage while preventing nuisance tripping. A standard Class A GFCI breaker has a 5mA trip threshold and is strictly designed for personnel shock protection.
No. The National Electrical Code (NEC) requires Class A GFCI protection with a 5mA trip threshold for residential bathroom, kitchen, and outdoor receptacles to protect personnel. This 30mA equipment protection breaker does not meet those personnel safety requirements.
Ground Fault Equipment Protection (GFEP) breakers are typically used to protect electrical equipment that may have inherent low-level current leakage. Common applications include pipe heat tracing tapes, roof snow melting equipment, and industrial heating systems.
The QC series features a cable-in/cable-out, feed-thru design using box lugs, meaning it does not plug onto a traditional loadcenter bus bar. It mounts to the backpan using Eaton Quicklag base mounting plates designed specifically for QC series breakers.
The breaker is equipped with a pigtail neutral. You must route and terminate this attached white pigtail wire directly to the neutral bus bar in the panelboard to properly power the internal ground fault detection circuitry.
Yes. Eaton acquired Cutler-Hammer and continues to manufacture the Quicklag circuit breaker family. Units labeled under either brand with the QCGFEP1030 catalog number are physically and functionally identical.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.