Part of the BR family, the Eaton GFTCB130 provides 30A of ground fault protection for residential and commercial applications. It features a 5mA trip sensitivity and self-test functionality to ensure ongoing safety compliance in wet locations. This single-pole plug-on breaker mounts into Eaton BR load centers, plus legacy Westinghouse, Challenger, and Bryant panels. It serves as a direct replacement for the older GFCB130. Rated for 10 kAIC at 120/240VAC, it includes a pigtail neutral.
CSA C22.2 No. 144, Federal Spec W-C375, UL 489, UL 943
Approval
CSA, UL
Temp Rating
40C
Construction Features
Self-Test
Product FAQs
8 answers
Which load centers are compatible with the GFTCB130 circuit breaker?
This plug-on breaker is designed for use in Eaton BR load centers. It is also backward compatible with legacy Westinghouse, Challenger, Bryant, and Novaline panels that accept Type BR breakers.
What is the ground fault trip threshold for this breaker?
The GFTCB130 features a 5mA trip sensitivity, classifying it as a Class A Ground Fault Circuit Interrupter (GFCI) for personnel protection in wet locations.
How is the neutral connected on the GFTCB130?
This breaker features a pigtail neutral connection. The coiled white pigtail wire must be connected directly to the panel neutral bus bar, while the load neutral wire connects directly to the designated neutral terminal on the breaker.
Does this GFCI breaker require a dedicated neutral wire for the circuit?
Yes. Because it is a 1-pole GFCI breaker, the circuit it protects cannot share a neutral wire with another circuit. A shared neutral will cause the breaker to trip immediately upon sensing an imbalance.
Can the GFTCB130 replace older GFCB130 breakers?
Yes, the GFTCB130 serves as a direct replacement for the older Cutler-Hammer GFCB130 model.
Does this breaker provide arc fault (AFCI) protection?
No, the GFTCB130 is strictly a Ground Fault Circuit Interrupter (GFCI). It does not provide arc fault protection. If your application requires both, you will need a dual-function AFCI/GFCI breaker.
What wire sizes are accepted by the box lugs on this 30A breaker?
The terminal lugs on the GFTCB130 accept copper or aluminum wiring ranging from 14 AWG to 4 AWG. Always verify the appropriate wire gauge for your specific 30A application based on local electrical codes.
Does the GFTCB130 include a self-test feature?
Yes, this breaker includes self-test functionality to ensure ongoing safety compliance. It periodically runs an internal diagnostic to verify that the ground fault detection circuitry is functioning properly.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.
Reviews
Review summary
Customers rate this product 5.0 out of 5 based on 1 review.