| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124100 |
| Series | TED |
| Amperage | 100A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Motor Operator |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free Mechanism |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124100-R |
| Series | TED |
| Amperage | 100A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Motor Operator |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free Mechanism |
ABB / General ElectricTED124090
ABB / General ElectricTED124080
ABB / General ElectricTED124070
ABB / General ElectricTED124060
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED124100 |
| Series | TED |
| Amperage | 100A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Panelboards |
| Wire Gauge | 3 AWG - 3/0 AWG (Cu), 1 AWG - 3/0 AWG (Al) |
| Max Wire | 3/0 AWG |
| Min Wire | 3 AWG (Cu), 1 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Motor Operator |
|---|---|
| Accessories | Lugs (TCAL15) |
| Standards | CSA C22.2 No. 5, HACR Rated, NEMA AB 1, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Non-Interchangeable Trip, Reverse Feed, Quick-Make/Quick-Break, Trip-Free Mechanism |
This bolt-on circuit breaker is designed for installation in GE A-Series and Spectra Series panelboards. It mounts directly to the internal bus structure of these panels.
Yes. Since ABB acquired GE Industrial Solutions, legacy E-Frame breakers can often be modernized using the ABB Tmax XT1 platform. Upgrading requires an appropriate retrofit kit designed for your specific panelboard.
The standard load lug kit for this E150 frame breaker is the TCAL15. It accepts 3 AWG to 3/0 AWG copper wire or 1 AWG to 3/0 AWG aluminum wire.
It is rated for DC applications up to 250VDC. When wiring for direct current, you must observe proper polarity and route the positive and negative conductors through the two poles as specified by the manufacturer wiring diagrams.
Yes. GE TEB, TED, and THED series breakers are suitable for reverse feed applications. This allows power to be supplied to either the line or load terminals without affecting the protective functions.
It features a non-interchangeable, fixed thermal-magnetic trip unit. The thermal element protects against prolonged overloads by heating up and tripping the breaker, while the magnetic element provides instantaneous protection against severe short circuits.
Yes. When a fault occurs, the handle moves to a center position between ON and OFF. To reset the mechanism, you must move the handle to the extreme OFF position before turning it back ON.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.