ABB / General ElectricTED134015WL
Quantity
Re-Certified
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136015WL |
| Series | TED |
| Amperage | 15A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Lug Kits |
|---|---|
| Accessories | Line & Load Lugs (TCAL12) |
| Standards | HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Trip-Free Mechanism |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136015WL-R |
| Series | TED |
| Amperage | 15A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Lug Kits |
|---|---|
| Accessories | Line & Load Lugs (TCAL12) |
| Standards | HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Trip-Free Mechanism |
ABB / General ElectricTED134015WL
ABB / General ElectricTED134020WL
ABB / General ElectricTED136020WL
ABB / General ElectricTED134010WL
| Brand | ABB / General Electric |
|---|---|
| Part Number | TED136015WL-R |
| Series | TED |
| Amperage | 15A |
| Poles | 3 |
| Mounting Style | Unit Mount |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 18kA @ 240VAC, 18kA @ 480VAC, 14kA @ 600VAC, 10kA @ 250VDC, 10kA @ 500VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | Individual Enclosures, Switchboards, Motor Control Centers |
| Wire Gauge | 14-3 AWG (Cu), 12-1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Bell Alarm, Lug Kits |
|---|---|
| Accessories | Line & Load Lugs (TCAL12) |
| Standards | HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Trip-Free Mechanism |
The WL designation means the circuit breaker includes factory-installed lugs on both the line and load sides. These terminals accommodate 14 to 3 AWG copper or 12 to 1 AWG aluminum conductors.
This unit-mount breaker is designed for installation in individual enclosures, motor control centers, and switchboards that accept GE E150 Line circuit breakers.
Both are E150 Line molded case circuit breakers with identical physical dimensions. The TED frame provides standard interrupting capacity, while the THED frame features enhanced internal barriers to achieve higher short-circuit interrupting ratings.
Yes, this thermal-magnetic breaker is rated for DC applications. It provides a 10kA interrupting capacity at both 250VDC and 500VDC.
As a feed-thru, unit-mount breaker, it bolts directly to the backpan or mounting surface of the enclosure and wires directly to the line and load terminals, rather than plugging into a panelboard busbar.
No, the TED136015WL features a fixed thermal-magnetic trip unit. Both the long-time overload and instantaneous short-circuit (LI) trip functions are factory set and cannot be adjusted in the field.
ABB acquired GE Industrial Solutions in 2018. Depending on the exact manufacturing date, the TED136015WL may feature either the General Electric or ABB logo. The physical dimensions, electrical specifications, and UL listings remain identical across both brands.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.