| Brand | ABB / General Electric |
|---|---|
| Part Number | THED124050 |
| Series | THED |
| Amperage | 50A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards, Motor Control Centers |
| Wire Gauge | 14 AWG - 3 AWG (Cu), 12 AWG - 1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Reverse Feed, Non-Interchangeable Trip, High Interrupting Capacity |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED124050-R |
| Series | THED |
| Amperage | 50A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards, Motor Control Centers |
| Wire Gauge | 14 AWG - 3 AWG (Cu), 12 AWG - 1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Reverse Feed, Non-Interchangeable Trip, High Interrupting Capacity |
ABB / General ElectricTHED124060
ABB / General ElectricTHED124040
ABB / General ElectricTHED124070
ABB / General ElectricTHED124030
| Brand | ABB / General Electric |
|---|---|
| Part Number | THED124050 |
| Series | THED |
| Amperage | 50A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC, 480VAC, 250VDC |
| Phase | 1 |
| AIC Rating | 65kA @ 240VAC, 25kA @ 480VAC, 10kA @ 250VDC |
| Frame Type | TED |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards, Motor Control Centers |
| Wire Gauge | 14 AWG - 3 AWG (Cu), 12 AWG - 1 AWG (Al) |
| Max Wire | 3 AWG (Cu), 1 AWG (Al) |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch |
|---|---|
| Accessories | Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489, NEMA AB-1 |
| Approval | CSA, HACR, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, HID Rated, Reverse Feed, Non-Interchangeable Trip, High Interrupting Capacity |
This bolt-on breaker is designed for direct installation into the busbars of GE A-Series and Spectra Series panelboards, as well as compatible motor control centers used in commercial and industrial power systems.
Yes. The THED124050 shares the same physical E150 frame dimensions as the standard TED124050 but offers a higher interrupting capacity, making it a direct, backward-compatible upgrade.
Both belong to the E150 frame family and are physically interchangeable. The THED series is the high-interrupting version, offering greater fault current protection compared to the standard TED series.
Yes, GE E150 frame breakers, including the THED series, are suitable for reverse feed applications.
When the breaker trips, the operating handle moves to a center position midway between ON and OFF. To reset the mechanism, the handle must be pushed to the extreme OFF position before being turned back ON.
No. The breaker features a trip-free mechanism that operates independently of the manual handle, ensuring it will still trip during an overload or short circuit even if the handle is physically held in the ON position.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.