| Brand | ABB / General Electric |
|---|---|
| Part Number | THHQB32060 |
| Series | THHQB |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC |
| Frame Type | THQB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE A-Series Panelboards, GE AQ Panelboards, ReliaGear Panelboards |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Internal Common Trip, Non-Interchangeable Trip, Quick-Make/Quick-Break, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THHQB32060-R |
| Series | THHQB |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC |
| Frame Type | THQB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE A-Series Panelboards, GE AQ Panelboards, ReliaGear Panelboards |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Internal Common Trip, Non-Interchangeable Trip, Quick-Make/Quick-Break, Reverse Feed |
ABB / General ElectricTHHQB32070
ABB / General ElectricTHHQB32050
ABB / General ElectricTHHQB32045
ABB / General ElectricTHHQB32040
| Brand | ABB / General Electric |
|---|---|
| Part Number | THHQB32060 |
| Series | THHQB |
| Amperage | 60A |
| Poles | 3 |
| Mounting Style | Bolt-On |
| Voltage | 240VAC |
| Phase | 3 |
| AIC Rating | 22kA @ 240VAC |
| Frame Type | THQB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE A-Series Panelboards, GE AQ Panelboards, ReliaGear Panelboards |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Internal Common Trip, Non-Interchangeable Trip, Quick-Make/Quick-Break, Reverse Feed |
No. The THHQB32060 is a bolt-on breaker designed strictly for commercial and industrial panelboards like the GE A-Series, AQ, and ReliaGear lines. Residential PowerMark panels require plug-in circuit breakers, such as the THQL series.
The difference lies in their short-circuit interrupting capacity. THQB breakers are rated at 10kAIC, while THHQB models like this one provide a higher 22kAIC rating. Both share the identical bolt-on mounting configuration and physical dimensions.
You may receive a unit branded as either General Electric or ABB. Following ABB's acquisition of GE Industrial Solutions, identical Q-Line circuit breakers are distributed under both brand names depending on the manufacturing date.
Yes. This breaker carries an official HACR rating, meaning it is approved for the unique inrush currents and continuous loads associated with motor-driven heating, air conditioning, and refrigeration equipment.
Yes. This thermal magnetic breaker has no directional line or load restrictions and is suitable for reverse feed applications. Because it physically bolts directly to the panel bus, it inherently satisfies National Electrical Code fastening requirements for back-fed main breakers without requiring an additional hold-down kit.
Yes. The breaker features an internal common trip mechanism. If an overload or short circuit occurs on any single phase, all three poles will open simultaneously. This provides critical safety by preventing single-phasing damage to three-phase equipment.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.