ABB / General ElectricTHQC2160WL
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC2160 |
| Series | THQC |
| Amperage | 60A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | DIN Rail Systems, OEM Panels, Enclosures, Control Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC2160-R |
| Series | THQC |
| Amperage | 60A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | DIN Rail Systems, OEM Panels, Enclosures, Control Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
ABB / General ElectricTHQC2160WL
ABB / General ElectricTHQC2170
ABB / General ElectricTHQC2170WL
ABB / General ElectricTHQC2150
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC2160 |
| Series | THQC |
| Amperage | 60A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | DIN Rail Systems, OEM Panels, Enclosures, Control Panels |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Padlock Attachment |
|---|---|
| Accessories | Line & Load Lugs |
| Standards | CSA C22.2 No. 5, NEMA AB 1, UL 489 |
| Approval | CSA, HACR, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Non-Interchangeable Trip |
The THQC2160 is a lug-to-lug (cable-in, cable-out) breaker that mounts on a standard 35mm DIN rail. This makes it ideal for OEM control panels and standalone enclosures that do not use a standard load center busbar.
While all belong to the GE Q-Line family of compact 1-inch per pole breakers, they differ in their mounting methods. THQC is a lug-to-lug breaker designed for 35mm DIN rail mounting. THQB is a bolt-on breaker, and THQL is a plug-in breaker for standard GE load centers.
No, standard GE PowerMark load centers require plug-in THQL or THQP breakers. The THQC2160 is a DIN rail-mounted, lug-to-lug breaker typically used in control panels or OEM equipment, and it will not attach to residential panel busbars.
Yes, because this is a lug-to-lug breaker, it features built-in mechanical lugs on both the line and load sides. These lugs are dual-rated for both copper (Cu) and aluminum (Al) conductors and accept wire sizes from 8 AWG to 3 AWG.
Yes, this Q-Line circuit breaker is UL Listed as HACR rated. This means it is approved for use with heating, air conditioning, and refrigeration equipment that requires this specific overcurrent protection standard.
The LI designation indicates that the thermal-magnetic trip unit provides Long-Time (thermal) protection against sustained overloads and Instantaneous (magnetic) protection against short circuits. Both the thermal and magnetic trip points are fixed on this model.
ABB acquired GE Industrial Solutions in 2018. The THQC2160 is part of the legacy GE Q-Line, but new stock is now manufactured and branded under ABB. Both brand names represent the exact same product and are fully interchangeable.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.