ABB / General ElectricTHQC2170WL
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC2170 |
| Series | THQC |
| Amperage | 70A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | DIN Rail Systems, OEM Panels, Enclosures |
| Wire Gauge | 6-1/0 AWG (Cu), 4-1/0 AWG (Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 6 AWG (Cu), 4 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment, Mounting Feet |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Visual Trip Indicator, Non-Interchangeable Trip, Reverse Feed |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC2170-R |
| Series | THQC |
| Amperage | 70A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | DIN Rail Systems, OEM Panels, Enclosures |
| Wire Gauge | 6-1/0 AWG (Cu), 4-1/0 AWG (Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 6 AWG (Cu), 4 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment, Mounting Feet |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Visual Trip Indicator, Non-Interchangeable Trip, Reverse Feed |
ABB / General ElectricTHQC2170WL
ABB / General ElectricTHQC2180WL
ABB / General ElectricTHQC2180
ABB / General ElectricTHQC2160
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQC2170 |
| Series | THQC |
| Amperage | 70A |
| Poles | 2 |
| Mounting Style | DIN Rail |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Lugs |
|---|---|
| For Use With | DIN Rail Systems, OEM Panels, Enclosures |
| Wire Gauge | 6-1/0 AWG (Cu), 4-1/0 AWG (Al) |
| Max Wire | 1/0 AWG |
| Min Wire | 6 AWG (Cu), 4 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Padlock Attachment, Mounting Feet |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break, Visual Trip Indicator, Non-Interchangeable Trip, Reverse Feed |
The THQC2170 is a Q-Line breaker designed for use in DIN rail systems, OEM panels, and standalone enclosures. Unlike standard plug-on residential breakers, it uses a bolt-on connection and lug terminals for feed-through wiring.
No. While both belong to the GE Q-Line family, THQB breakers are strap-in models that bolt directly to the bus bar in compatible panelboards. The THQC2170 is a wire-in (feed-through) breaker with lugs on both ends, designed for DIN rail systems or OEM enclosures.
The load and line lugs accept 6 to 1/0 AWG copper (Cu) conductors or 4 to 1/0 AWG aluminum (Al) conductors. Ensure proper torque specifications are followed during installation.
The LI designation indicates fixed Long-Time and Instantaneous trip functions. The thermal (Long-Time) element provides delayed tripping for sustained overloads, while the magnetic (Instantaneous) element trips immediately in the event of a short circuit.
This breaker is rated to safely interrupt up to 10,000 amps (10kAIC) at 120/240VAC. It must not be installed in electrical systems where the available short-circuit current exceeds this threshold.
ABB acquired GE Industrial Solutions, meaning Q-Line breakers like the THQC2170 may carry either the ABB or GE brand logo. Both versions share the same form factor, specifications, and UL listings.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.