  • 125A
  • 3 Pole
  • I-Line
Square D HLA36125
Molded Case Circuit Breaker
Brand Square D
SKU HLA36125
Select Item Condition
Earn 3016 SuperPoints
  • 125A
  • 3 Pole
  • I-Line

Quantity

Bulk Pricing
Send your parts list for a volume quote.
Square D HLA36125 - 125A 3 Pole Molded Case Circuit Breaker

Square D HLA36125 - 125A 3 Pole Molded Case Circuit Breaker

New

$3,016.00 In Stock

Quantity

Similar Items

Description

Part of the PowerPacT H-Frame series, this 125A thermal-magnetic breaker provides robust long-time and instantaneous (LI) protection for demanding industrial applications. It installs into Square D I-Line panelboards and switchboards, utilizing a plug-on phase connection for rapid deployment. Featuring a 100kAIC interrupting rating at 480VAC, the current-limiting design ensures superior system reliability while maintaining compliance with UL 489 and IEC standards for commercial switchgear.

Specifications

Key specifications
Brand Square D
Part Number HLA36125
Series HLA
Amperage 125A
Poles 3
Mounting Style I-Line
Voltage 240VAC, 480VAC, 600VAC, 250VDC
Phase 3
AIC Rating 125kA @ 240VAC, 100kA @ 480VAC, 50kA @ 600VAC, 20kA @ 250VDC
Fit and installation
Frame Type HLA
Terminal Type Lugs
For Use With Square D I-Line Panelboards, Square D I-Line Switchboards
Wire Gauge 14-3/0 AWG (Al/Cu)
Max Wire 3/0 AWG
Min Wire 14 AWG
Protection and operation
Trip Technology Thermal Magnetic
Trip Function Code LI
Trip Function Long-Time, Instantaneous
Trip Adjustability Fixed Thermal, Fixed Magnetic
Standards and features
Available Options Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle
Accessories Load Side Lugs Included
Standards CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489
Approval CE, CSA, HACR, NOM, UL
Temp Rating -25C to 70C
Construction Features HACR Rated, Current Limiting, Non-Interchangeable Trip, RoHS Compliant, Mercury Free, PVC Free

Product FAQs

9 answers
Which panelboards are compatible with the HLA36125?

This breaker is designed exclusively for Square D I-Line panelboards and switchboards. It mounts directly to the interior busbar stack using an integrated plug-on connection with a standard ABC phase arrangement.

How much mounting space does the HLA36125 require on the panel bus?

As a 3-pole PowerPacT H-Frame circuit breaker, it occupies 4.5 inches of vertical mounting space on the I-Line bus stack.

What does the "L" in the HLA36125 catalog number represent?

In the Square D PowerPacT nomenclature, the "L" designates the specific interrupting capacity class. For the H-Frame series, the L-class provides a high-tier interrupting rating of 100kA at 480VAC and 125kA at 240VAC.

Can the HLA36125 replace lower-rated H-Frame circuit breakers?

Yes. Because the HLA36125 has a high 100kA at 480V interrupting capacity, it can safely replace similarly configured 125-amp I-Line breakers with lower short-circuit ratings, such as the HDA36125, HGA36125, and HJA36125.

Does the HLA36125 come with both line and load lugs?

No. Because this is an I-Line breaker, the line side uses a plug-on jaw assembly that attaches directly to the panelboard bus. Mechanical lugs are only provided on the load side, which accept 14 to 3/0 AWG copper or aluminum wire.

Can the thermal and magnetic trip points be adjusted on the HLA36125?

No. This specific breaker model features fixed thermal and fixed magnetic trip elements. It provides standard Long-Time (L) and Instantaneous (I) overcurrent protection that cannot be modified in the field.

Is there a way to manually test the trip mechanism on this breaker?

Yes, PowerPacT H-Frame breakers include a built-in push-to-trip button located on the front cover. This allows you to manually trip the breaker for safety testing and routine preventive maintenance without needing to apply a fault current.

How do you properly reset the HLA36125 after it has tripped?

When a fault occurs, the breaker handle moves to a center tripped position. To restore power, you must first push the handle completely to the "OFF" position to reset the internal toggle mechanism, and then push it firmly back to the "ON" position.

Can field-installable accessories be added to the HLA36125?

Yes, the PowerPacT H-Frame design supports various field-installable internal accessories. Auxiliary components like shunt trips, alarm switches, and undervoltage releases can be installed securely under the front cover.

SuperClub

Join free. Get 500 SuperPoints.

Earn points on eligible purchases and redeem them at checkout.

100 SuperPoints = $1 off.

Warranties

60-Day Warranty

Your purchase includes 60 days of SuperBreakers warranty coverage.

Get a Quote

Don’t see what you’re looking for?

We source obsolete and hard-to-find parts every day.

Shipping

Free Shipping Policy

Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.

Read our full shipping policy

Same Day Shipping

We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.

Expedited Shipments

Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.

International Shipping

All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.