Schneider Electric HLA36150 Molded Case Circuit Breaker
- 150A
- 3 Pole
- I-Line
Quantity
Schneider Electric HLA36150 - 150A 3 Pole Molded Case Circuit Breaker
New
Quantity
Quantity
Schneider Electric HLA36150 - 150A 3 Pole Molded Case Circuit Breaker
New
Quantity
| Brand | Schneider Electric |
|---|---|
| Part Number | HLA36150 |
| Series | HLA |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | I-Line |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 125kA @ 240VAC, 100kA @ 480VAC, 50kA @ 600VAC, 20kA @ 250VDC, 50kA @ 500VDC |
| Frame Type | HLA |
|---|---|
| Terminal Type | Lugs |
| For Use With | Square D I-Line Panelboards, Switchboards |
| Wire Gauge | 14-3/0 AWG (Al/Cu) |
| Max Wire | 3/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle, Lug Kits, Terminal Shields |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, IEC, NOM, UL |
| Temp Rating | 40C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Non-Interchangeable Trip, 80% Rated, Dual-Break Rotary Contact Structure |
Quantity
Schneider Electric HLA36150 - 150A 3 Pole Molded Case Circuit Breaker
Re-Certified
Quantity
| Brand | Schneider Electric |
|---|---|
| Series | HLA |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | I-Line |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 125kA @ 240VAC, 100kA @ 480VAC, 50kA @ 600VAC, 20kA @ 250VDC, 50kA @ 500VDC |
| Frame Type | HLA |
|---|---|
| Terminal Type | Lugs |
| For Use With | Square D I-Line Panelboards, Switchboards |
| Wire Gauge | 14-3/0 AWG (Al/Cu) |
| Max Wire | 3/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle, Lug Kits, Terminal Shields |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, IEC, NOM, UL |
| Temp Rating | 40C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Non-Interchangeable Trip, 80% Rated, Dual-Break Rotary Contact Structure |
Description
Built for commercial and industrial power distribution, this 150A PowerPacT H-Frame circuit breaker provides reliable thermal-magnetic protection. The unit installs into Square D I-Line panelboards and switchboards, utilizing a plug-on phase connection for efficient setup. Rated at 100 kAIC at 480VAC, it delivers exceptional current-limiting performance. The breaker features a dual-break rotary contact structure that reduces peak current during short circuit faults.Specifications
| Brand | Schneider Electric |
|---|---|
| Part Number | HLA36150 |
| Series | HLA |
| Amperage | 150A |
| Poles | 3 |
| Mounting Style | I-Line |
| Voltage | 240VAC, 480VAC, 600VAC, 250VDC, 500VDC |
| Phase | 3 |
| AIC Rating | 125kA @ 240VAC, 100kA @ 480VAC, 50kA @ 600VAC, 20kA @ 250VDC, 50kA @ 500VDC |
| Frame Type | HLA |
|---|---|
| Terminal Type | Lugs |
| For Use With | Square D I-Line Panelboards, Switchboards |
| Wire Gauge | 14-3/0 AWG (Al/Cu) |
| Max Wire | 3/0 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Adjustable Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment, Motor Operator, Rotary Handle, Lug Kits, Terminal Shields |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, IEC 60947-2, NEMA AB 1, UL 489 |
| Approval | CE, CSA, IEC, NOM, UL |
| Temp Rating | 40C |
| Construction Features | Current Limiting, HACR Rated, Reverse Feed, Non-Interchangeable Trip, 80% Rated, Dual-Break Rotary Contact Structure |
Product FAQs
6 answersWhat are the load side lug torque specifications for the HLA36150?
The load side lugs should be tightened to 44.3 lb-in for 14-10 AWG conductors, and 124 lb-in for 8-3/0 AWG conductors.
Is this circuit breaker rated for 80 percent or 100 percent continuous current?
The HLA36150 carries a standard 80 percent continuous current rating.
Which replacement lug kit is compatible with the load side of this breaker?
The standard mechanical lug kit is part number AL150HD, which accepts 14-3/0 AWG aluminum or copper wire.
What panelboards are compatible with the HLA36150?
This breaker features a plug-on line connection exclusively designed for installation in Square D I-Line panelboards and switchboards.
What does the letter L designate in the HLA36150 catalog number?
The letter L indicates the breaking capacity code within the PowerPacT H-Frame series, corresponding to an interrupting rating of 100kA at 480VAC.
What is the phase connection configuration for this breaker?
This 3-pole I-Line breaker is factory-configured with a standard ABC phase connection.
SuperClub
Join free. Get 500 SuperPoints.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Warranties
Add an extra year of protection
60-Day Warranty
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
Get a Quote
Don’t see what you’re looking for?
We source obsolete and hard-to-find parts every day.
Shipping
Free Shipping Policy
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
Same Day Shipping
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Expedited Shipments
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
International Shipping
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.