| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL1115AF2 |
| Series | THQL |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE Q-Line Load Centers, GE PowerMark Gold Load Centers, ABB ReliaHome Load Centers |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Special Classification | AFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | CSA C22.2 No. 5, UL 489, UL 1699, HACR, SWD |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break, Visual Trip Indicator |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Series | THQL |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE Q-Line Load Centers, GE PowerMark Gold Load Centers, ABB ReliaHome Load Centers |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Special Classification | AFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | CSA C22.2 No. 5, UL 489, UL 1699, HACR, SWD |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break, Visual Trip Indicator |
ABB / General ElectricTHQL1115AF
ABB / General ElectricTHQL1120AF2
ABB / General ElectricTHQL1120AF2S
ABB / General ElectricTHQL1120AFP2
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL1115AF2 |
| Series | THQL |
| Amperage | 15A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQL |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE Q-Line Load Centers, GE PowerMark Gold Load Centers, ABB ReliaHome Load Centers |
| Wire Gauge | 14-8 AWG (Cu), 12-8 AWG (Al) |
| Max Wire | 8 AWG |
| Min Wire | 14 AWG (Cu), 12 AWG (Al) |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Special Classification | AFCI |
|---|---|
| Available Options | Padlock Attachment |
| Accessories | Pigtail Neutral |
| Standards | CSA C22.2 No. 5, UL 489, UL 1699, HACR, SWD |
| Approval | CSA, UL |
| Temp Rating | 10C to 50C |
| Construction Features | HACR Rated, SWD Rated, Quick-Make/Quick-Break, Visual Trip Indicator |
It is designed for use in GE Q-Line, GE PowerMark Gold, and ABB ReliaHome load centers that accept 1-inch plug-in breakers.
The THQL1115AF2 features a pigtail neutral wire. This pigtail must be routed and connected directly to the neutral bus bar in your panel to power the arc fault circuitry.
As a Combination Arc Fault Circuit Interrupter (CAFCI), this unit detects both high-energy parallel arcs and low-energy series arcs. Older branch or feeder AFCI models only detected parallel arcs.
Yes. The THQL1115AF2 is the direct replacement for the obsolete THQL1115AF. The AF2 version upgrades the protection to a Combination AFCI to meet modern NEC requirements.
Yes, this breaker carries both SWD (Switching Duty) and HACR (Heating, Air Conditioning, and Refrigeration) ratings. It can be used to switch 120V fluorescent lighting circuits and protect dedicated HVAC loads.
The box lugs accept 14 to 8 AWG copper conductors or 12 to 8 AWG aluminum conductors. Ensure proper torque is applied during installation.
No, the THQL1115AF2 is strictly an Arc Fault Circuit Interrupter (AFCI). If your circuit requires both arc fault and ground fault protection, you will need a Dual Function (DFCI) breaker instead.
It requires a single 1-inch space on the bus bar in a compatible GE or ABB load center.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.