| Brand | ABB / General Electric |
|---|---|
| Part Number | THQB2150 |
| Series | THQB |
| Amperage | 50A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE A-Series Panelboards, GE AQ Lighting Panels |
| Wire Gauge | 8-3 AWG (Cu/Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Internal Common Trip, Quick-Make/Quick-Break |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQB2150-R |
| Series | THQB |
| Amperage | 50A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE A-Series Panelboards, GE AQ Lighting Panels |
| Wire Gauge | 8-3 AWG (Cu/Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Internal Common Trip, Quick-Make/Quick-Break |
ABB / General ElectricTHQB2150ST1
ABB / General ElectricTHQB2145
ABB / General ElectricTHQB2160ST1
ABB / General ElectricTHQB2140
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQB2150 |
| Series | THQB |
| Amperage | 50A |
| Poles | 2 |
| Mounting Style | Bolt-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Frame Type | THQB |
|---|---|
| Terminal Type | Box Lugs |
| For Use With | GE A-Series Panelboards, GE AQ Lighting Panels |
| Wire Gauge | 8-3 AWG (Cu/Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed |
| Available Options | Shunt Trip, Auxiliary Switch, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Side Lugs Included |
| Standards | CSA C22.2 No. 5, HACR, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Internal Common Trip, Quick-Make/Quick-Break |
This breaker is designed for use in standard GE A-Series panelboards and GE AQ lighting panels that require a bolt-on connection. It mounts directly to the panel bus.
The THQB2150 is a bolt-on circuit breaker intended for commercial panels like the AQ lighting panel line. THQL breakers are plug-in style breakers typically used in residential PowerMark load centers. They are not interchangeable.
ABB acquired GE Industrial Solutions. Depending on the manufacturing date, new stock of this circuit breaker may carry GE branding, ABB branding, or a combination of both. The fit and function remain identical.
Yes, this breaker carries an HACR rating, making it suitable for use with heating, air conditioning, and refrigeration equipment motor loads.
The THHQB2150 is the 22kAIC version of this breaker. The THQB2150 is only rated for 10kAIC. You cannot replace a THHQB with a THQB unless the panel and circuit strictly require a 10kAIC maximum interrupt rating.
Yes, standard GE Q-Line miniature breakers like the THQB series are suitable for reverse feed applications. They can be back-fed when installed according to local electrical codes.
The LI designation means this thermal magnetic breaker provides Long-Time overload and Instantaneous short circuit protection. These standard trip settings are fixed and non-adjustable.
The factory box lugs accept conductors from 8 AWG up to 3 AWG. The terminals are dual-rated for both copper and aluminum wiring.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.