Eaton / Cutler-HammerCHFN120GF
Quantity
New
Quantity
Eaton / Cutler-HammerCHFN120GF
Eaton / Cutler-HammerCHFN115GF
| Brand | Eaton / Cutler-Hammer |
|---|---|
| Part Number | CHGF120 |
| Series | CH |
| Amperage | 20A |
| Poles | 1 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | Eaton CH Load Centers |
| Wire Gauge | 14-6 AWG (Cu/Al) |
| Max Wire | 6 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment, Handle Lock |
| Accessories | Trip Flag |
| Standards | CSA C22.2, HACR, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, SWD Rated, Visual Trip Indicator, Self-Test |
This breaker is designed exclusively for use in Eaton Type CH load centers. It requires a 3/4-inch space per pole and is not compatible with Eaton BR or other manufacturer panels.
Yes, this breaker features a pigtail neutral. You must connect the attached white pigtail wire directly to the neutral bus bar in your load center for the ground-fault protection to function properly.
This is a Class A GFCI breaker, meaning it is designed to trip when it detects a ground-fault current of 5mA. This provides personnel protection against electrical shock in wet areas like kitchens and bathrooms.
The CHFGF120 is the updated version of the CHGF120. The F in the CHFGF120 part number indicates the addition of a mechanical trip flag, which provides a clear visual indication when the breaker has tripped. Both models offer the same ground-fault protection and fit the same Type CH panels.
Yes, modern Eaton GFCI breakers perform routine self-tests to ensure the ground-fault detection circuitry is working correctly. If the breaker fails the internal self-test, it will automatically trip and prevent power from being restored.
Yes, but because this is a pigtail neutral breaker, it will not utilize the plug-on neutral bus. You must still route and connect the attached white pigtail wire to the neutral bar in the panel for the ground-fault protection to operate.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.