ABB / General ElectricTEB111060
Quantity
New
Quantity
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB111050 |
| Series | TEB |
| Amperage | 50A |
| Poles | 1 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 125VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 120VAC, 5kA @ 125VDC |
| Frame Type | TEB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Visual Trip Indicator |
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB111050-R |
| Series | TEB |
| Amperage | 50A |
| Poles | 1 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 125VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 120VAC, 5kA @ 125VDC |
| Frame Type | TEB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Visual Trip Indicator |
ABB / General ElectricTEB111060
ABB / General ElectricTEB111040
ABB / General ElectricTEB111020
ABB / General ElectricTEB111015
| Brand | ABB / General Electric |
|---|---|
| Part Number | TEB111050 |
| Series | TEB |
| Amperage | 50A |
| Poles | 1 |
| Mounting Style | Bolt-On |
| Voltage | 120VAC, 125VDC |
| Phase | 1 |
| AIC Rating | 10kA @ 120VAC, 5kA @ 125VDC |
| Frame Type | TEB |
|---|---|
| Terminal Type | Lugs |
| For Use With | GE A-Series Panelboards, GE Spectra Series Panelboards |
| Wire Gauge | 14-4 AWG (Cu/Al) |
| Max Wire | 4 AWG |
| Min Wire | 14 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LI |
| Trip Function | Long-Time, Instantaneous |
| Trip Adjustability | Fixed Thermal, Fixed Magnetic |
| Available Options | Shunt Trip, Auxiliary Switch, Undervoltage Release, Alarm Switch, Padlock Attachment |
|---|---|
| Accessories | Load Lugs |
| Standards | CSA C22.2 No. 5, UL 489 |
| Approval | CSA, UL |
| Temp Rating | 40C |
| Construction Features | HACR Rated, Reverse Feed, Non-Interchangeable Trip, Quick-Make/Quick-Break, Trip-Free Mechanism, Visual Trip Indicator |
This E-frame breaker is designed for bolt-on installation in GE A-Series and GE Spectra Series panelboards.
Yes, in addition to its 120VAC rating, this breaker is rated for DC applications up to 125VDC with an interrupting capacity of 5kAIC.
The factory-installed lugs accept 14 AWG to 4 AWG copper (Cu) or aluminum (Al) conductors.
It features a bolt-on connection, requiring it to be mechanically fastened to the panelboard bus with screws or bolts rather than snapping into place.
Yes. Following ABB's acquisition of GE Industrial Solutions, TEB series breakers are manufactured by ABB. They retain the original GE design, footprint, and catalog numbers for direct replacement.
No, this breaker features a fixed thermal and fixed magnetic trip unit. The long-time and instantaneous trip functions are factory set and cannot be adjusted in the field.
Torque requirements depend on the exact wire gauge used. Refer to the label on the side of the breaker or the manufacturer lug installation instructions for the correct inch-pound values.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.