ABB / General ElectricTHQL2140GF1
Quantity
New
Quantity
Quantity
Re-Certified
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL2140GF-R |
| Series | THQL |
| Amperage | 40A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | GE PowerMark Gold Load Centers, GE A-Series Panelboards, ABB ReliaHome Load Centers |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment, Auxiliary Switch |
| Accessories | Pigtail Neutral |
| Standards | HACR, NEMA AB 1, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break |
Quantity
New
Quantity
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL2140GF |
| Series | THQL |
| Amperage | 40A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | GE PowerMark Gold Load Centers, GE A-Series Panelboards, ABB ReliaHome Load Centers |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment, Auxiliary Switch |
| Accessories | Pigtail Neutral |
| Standards | HACR, NEMA AB 1, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break |
ABB / General ElectricTHQL2140GF1
ABB / General ElectricTHQL2140GFT2
ABB / General ElectricTHQL2145GFT2
ABB / General ElectricTHQL2150GF
| Brand | ABB / General Electric |
|---|---|
| Part Number | THQL2140GF |
| Series | THQL |
| Amperage | 40A |
| Poles | 2 |
| Mounting Style | Plug-On |
| Voltage | 120/240VAC |
| Phase | 1 |
| AIC Rating | 10kA @ 120/240VAC |
| Terminal Type | Box Lugs |
|---|---|
| For Use With | GE PowerMark Gold Load Centers, GE A-Series Panelboards, ABB ReliaHome Load Centers |
| Wire Gauge | 8-3 AWG (Cu), 8-3 AWG (Al) |
| Max Wire | 3 AWG |
| Min Wire | 8 AWG |
| Trip Technology | Thermal Magnetic |
|---|---|
| Trip Function Code | LIG |
| Trip Function | Long-Time, Instantaneous, Ground Fault |
| Trip Adjustability | Fixed |
| Special Classification | GFCI |
|---|---|
| Available Options | Padlock Attachment, Auxiliary Switch |
| Accessories | Pigtail Neutral |
| Standards | HACR, NEMA AB 1, UL 489, UL 943 |
| Approval | CSA, UL |
| Temp Rating | 60C to 75C |
| Construction Features | HACR Rated, Common Trip, Quick-Make/Quick-Break |
This breaker is designed for use in GE PowerMark Gold load centers, GE A-Series panelboards, and ABB ReliaHome load centers.
Yes. ABB acquired GE Industrial Solutions, so THQL breakers branded under either ABB or General Electric belong to the same product line and are fully interchangeable.
The THQL series features a standard 1-inch per pole design. As a 2-pole breaker, it requires two adjacent 1-inch spaces, taking up a total of 2 inches of bus space in the panel.
This breaker provides Class A 5mA ground fault protection, which is designed for personnel safety in wet or damp locations to meet NEC requirements.
The THQL2140GF features a pigtail neutral wire that must be connected directly to the neutral bus bar in the panel to enable proper ground fault detection.
The terminal lugs accept 8 AWG to 3 AWG copper or aluminum conductors.
Earn points on eligible purchases and redeem them at checkout.
100 SuperPoints = $1 off.
Your purchase includes 60 days of SuperBreakers warranty coverage.
Add a 1-year warranty extension in your cart.
We source obsolete and hard-to-find parts every day.
Parcel shipments with item value over $99 qualify for free economy shipping within the continental US. Please call to confirm special handling instructions. We do not charge a handling fee or require a minimum amount on any order. SuperBreakers does not ship on customer accounts.
We strive to ship out your items the same day the order is placed. In rare circumstances SuperBreakers may reserve up to 5 business days to consolidate orders for complete shipment.
Orders being shipped via Next Day Air, 2 Day Shipping or 3 Day Shipping must be received by 3 PM EST to guarantee same-day shipments. Expedited orders only ship on normal business days. Shipments will NOT be sent out on Saturdays and Sundays.
All International orders require a $1,000 minimum order threshold. Due to the special nature of these shipments, we require that these be placed with a SuperBreakers representative. Additional shipping and instructions will apply. All International Orders are Non-Cancel and Non-Refundable.